Notice
The network cable must be disconnected in order to prevent transmission of the data.
Fig. 3: Graphical representation of the yield data in the Internet portal
3.6.3 RS485 bus
The inverter communicates with other devices via an RS485 bus. The following applies:
n
The inverter has two RS485 interfaces (RJ45 sockets) on the lower side of the casing.
n
The beginning and end of the RS485 bus must be terminated; see
n
Standard RJ45 cables can be used as bus cables (Cat-5 patch cables, not supplied). Use an alter-
native data connection cable for longer connections; see
n
The inverters connected to the RS485 bus operate as
slaves.
Notice
The following inverters have compatible data interfaces and can be connected to the RS485 bus as
slaves:
–
StecaGrid 2020
–
StecaGrid 1800, 2300, 3010, 3000, 3600, 4200 and StecaGrid 1800x, 2300x, 3010x, 3600x,
4200x
–
StecaGrid 8000 3ph, StecaGrid 10000 3ph
–
StecaGrid 8000+ 3ph, StecaGrid 10000+ 3ph
Observe the manuals of these devices concerning the definition of addresses, termination and per-
missible data cables.
GB
747.431 | Z08 | 2014-01-31
98
Содержание coolcept StecaGrid 1800
Страница 76: ...DE 747 431 Z08 2014 01 31 76...
Страница 121: ...Entering system data 1 2 3 4 5 6 7 7 8 9 10 11 Fig 12 Data entry form for the system data GB 747 431 Z08 2014 01 31 121...
Страница 146: ...GB 747 431 Z08 2014 01 31 146...
Страница 147: ...1 Montage Installation Montage 148 2 Zertifikate Certificates Certificats 162 747 431 Z08 2013 12 10 147...
Страница 149: ...coolcept x 150 mm 240 mm 45 mm 210 mm 190 mm 320 mm 400 mm 748 339 Z01 747 431 Z08 2013 12 10 149...
Страница 162: ...2 Zertifikate Certificates Certificats 747 431 Z08 2013 12 10 162...
Страница 163: ...747 431 Z08 2013 12 10 163...
Страница 164: ...747431...