7
Troubleshooting
Faults are indicated by event messages as described below. The display flashes red. The
list of event
messages below contains information on troubleshooting and fault correction.
Structure
Event messages contain the following information:
①
Symbol for the type of event message
②
Date/time when the event occurred
③
ACTIVE
= cause of the event message is still present
or
Date/time
at which the cause of the event message was cor-
rected.
④
Cause of the event message
⑤
Counter:
No. of the displayed event messages / Total number
of event messages;
Max number of all event messages = 30
⑥
NEW
is displayed until the event message has been manually
confirmed via the
ESC
or
rs
button.
Function
Event message types
n
Type Information (symbol )
The inverter has detected an error that does not affect the feed-in process. The user does not
need to intervene.
n
Type Warning (symbol
)
The inverter has detected an error that may result in reduced yields. It is highly recommended
that you correct the cause of the error.
n
Type Error (symbol )
The inverter has detected a serious error. The inverter will not feed into the grid while this error
is present. Please contact your installer. More information is provided in the table below.
Display behaviour
New event messages are displayed immediately. The messages disappear after they have been con-
firmed or their causes have been corrected.
Note
When an event message is confirmed, the user thereby simply confirms that he/she has seen the
message. This does not correct the error that caused the event message to be shown!
If messages exist whose cause has been corrected but have not been confirmed then
*
is shown in
the status display. If an already confirmed error recurs then it is displayed again.
GB
747.431 | Z08 | 2014-01-31
128
Содержание coolcept StecaGrid 1800
Страница 76: ...DE 747 431 Z08 2014 01 31 76...
Страница 121: ...Entering system data 1 2 3 4 5 6 7 7 8 9 10 11 Fig 12 Data entry form for the system data GB 747 431 Z08 2014 01 31 121...
Страница 146: ...GB 747 431 Z08 2014 01 31 146...
Страница 147: ...1 Montage Installation Montage 148 2 Zertifikate Certificates Certificats 162 747 431 Z08 2013 12 10 147...
Страница 149: ...coolcept x 150 mm 240 mm 45 mm 210 mm 190 mm 320 mm 400 mm 748 339 Z01 747 431 Z08 2013 12 10 149...
Страница 162: ...2 Zertifikate Certificates Certificats 747 431 Z08 2013 12 10 162...
Страница 163: ...747 431 Z08 2013 12 10 163...
Страница 164: ...747431...