ATTENTION!
Danger of damage to the inverter or derating!
–
The mounting location must satisfy the following conditions:
–
The mounting location and immediate environment are permanently fixed, vertical, flat,
non-inflammable and not subject to constant vibration.
–
The permissible ambient conditions are conformed to; see Technical data
p. 133 et seqq.
–
The following free spaces must be present around the inverter:
Above/below: at least 200 mm
At the sides/in front: at least 60 mm
–
Do not install the inverter in areas where animals are kept.
–
Observe the connection ratings specified on the type plate.
–
The DC cables must not be connected to an earth potential (DC inputs and AC output are not
galvanically isolated).
ATTENTION!
When transmitting data over a public network:
–
Transmitting data over a public network can incur additional costs.
–
Data transmitted over a public network is not protected from unauthorised access by third-
parties.
Note
–
Avoid exposing the inverter to direct sunlight.
–
The display must be readable on the installed device.
GB
747.431 | Z08 | 2014-01-31
103
Содержание coolcept StecaGrid 1800
Страница 76: ...DE 747 431 Z08 2014 01 31 76...
Страница 121: ...Entering system data 1 2 3 4 5 6 7 7 8 9 10 11 Fig 12 Data entry form for the system data GB 747 431 Z08 2014 01 31 121...
Страница 146: ...GB 747 431 Z08 2014 01 31 146...
Страница 147: ...1 Montage Installation Montage 148 2 Zertifikate Certificates Certificats 162 747 431 Z08 2013 12 10 147...
Страница 149: ...coolcept x 150 mm 240 mm 45 mm 210 mm 190 mm 320 mm 400 mm 748 339 Z01 747 431 Z08 2013 12 10 149...
Страница 162: ...2 Zertifikate Certificates Certificats 747 431 Z08 2013 12 10 162...
Страница 163: ...747 431 Z08 2013 12 10 163...
Страница 164: ...747431...