Fig. 8: External conductor voltages in 2- and 3-phase grids with 100 V ... 127 V
4.4 Preparing the DC connections
DANGER!
Risk of death by electrocution!
–
–
coolcept: Opposing Multi-Contact connectors must be used for the DC cable to suit the
Multi-
Contact MC4 plug connectors (opposing connectors optionally available).
–
coolcept-x: Use the SunClix plug connectors provided to ensure that the specified degree of
protection is maintained.
ATTENTION!
Danger of damage to the inverter and the modules. Connect the opposing connectors for the DC
connections to the DC cable, observing the correct polarity.
1.
Attach the connector plug counterparts to the DC cable according to the manufacturer's
instructions; see Appendix.
2.
If legally prescribed (e.g. France), plug in the optionally available safety sleeves, according to
the manufacturer's instructions (Fig. 9).
Fig. 9: Safety sleeve unmounted (left) and mounted (right)
4.5 Preparing the data connection cable
If a data connection is required, use a standard RJ45 cable (patch cable, Cat5) or construct an
alternative data connection cable (see
GB
747.431 | Z08 | 2014-01-31
107
Содержание coolcept StecaGrid 1800
Страница 76: ...DE 747 431 Z08 2014 01 31 76...
Страница 121: ...Entering system data 1 2 3 4 5 6 7 7 8 9 10 11 Fig 12 Data entry form for the system data GB 747 431 Z08 2014 01 31 121...
Страница 146: ...GB 747 431 Z08 2014 01 31 146...
Страница 147: ...1 Montage Installation Montage 148 2 Zertifikate Certificates Certificats 162 747 431 Z08 2013 12 10 147...
Страница 149: ...coolcept x 150 mm 240 mm 45 mm 210 mm 190 mm 320 mm 400 mm 748 339 Z01 747 431 Z08 2013 12 10 149...
Страница 162: ...2 Zertifikate Certificates Certificats 747 431 Z08 2013 12 10 162...
Страница 163: ...747 431 Z08 2013 12 10 163...
Страница 164: ...747431...