Model SCSS-700 Installation Manual
1-2
53722
•
Supports conventional 2-wire & 4-wire detectors using the 8 Flexput™ circuits or SLC
zone modules.
•
999 software zones, 999 output groups.
•
Add 4 notification/auxiliary power circuits with each 5496 Intelligent Power Module.
•
Add 6 Flexput™ circuits with each 5895XL Remote Power Supply.
•
Interconnection capability for up to 8 panels.
1.1.2
Network System Hardware Features
•
The default network setup can contain up to eight SCSS-700 / SCSS-700ND panels
connected within a networked system providing a maximum addressable point capacity of
5,088.
•
The networked system can be configured to emulate a large virtual system or can be
segmented into separate sites for multiple building applications.
•
Each building is referred to as a “site”. All panels in a site operate as a single panel.
•
Panels can be interconnected using a BUS or CLASS A (style 7) topology.
•
Panels can be connected cost effectively via shielded twisted pair copper wire within
conduit when the panels are located no more than 20 feet apart and within the same room.
•
Panels separated by more than 20 feet or located in multiple buildings use IFP-RPT
network repeater hardware to provide up to 3000 ft. of separation with twisted pair copper
wire or up to 8dB loss of signal separation for fiber optic cable. All 3 methods of panel
connectivity can be used within the same networked system.
•
The network architecture provides true peer to peer capability allowing network
survivability for all hardware that remains operational in the event of partial system
failure.
1.1.3
Software Features
•
Advanced analog smoke detector features:
Three sensitivity settings (high, medium, low)
Automatic drift compensation
Maintenance alert region
Point status meets calibrated smoke test requirements for NFPA 72
Automatic day/night sensitivity adjustment
•
“JumpStart AutoProgramming” feature for easy programming
•
Non-volatile event history stores 1000 events per panel
•
A choice of output patterns available for notification outputs, including ANSI 3.41
temporal signal
•
Built-in synchronization appliance support for AMSECO, Gentex
®
, System Sensor
®
, and
Wheelock
®
.
Содержание SCSS-700
Страница 2: ......
Страница 12: ...SCSS 700 Installation Manual 8...
Страница 22: ...Model SCSS 700 Installation Manual 1 10 53722...
Страница 26: ...Model SCSS 700 Installation Manual 2 4 53722...
Страница 31: ...Before You Begin Installing 53722 3 5 Figure 3 1 Wire Routing Example...
Страница 42: ...Model SCSS 700 Installation Manual 3 16 53722...
Страница 92: ...Model SCSS 700 Installation Manual 4 50 53722...
Страница 130: ...Model SCSS 700 Installation Manual 8 8 53722 Figure 8 4 Example of Zone Events Mapped to output Groups and Patterns...
Страница 131: ...Programming Overview 53722 8 9 Figure 8 5 Example of Zone Events Mapped to Output Groups and Patterns on a Single Panel...
Страница 134: ...Model SCSS 700 Installation Manual 8 12 53722 Figure 8 9 Example of SCSS 700PK Software mapping Site Events...
Страница 148: ...Model SCSS 700 Installation Manual 8 26 53722...
Страница 192: ...Model SCSS 700 Installation Manual 9 44 53722...
Страница 250: ...SCSS 700 Installation Manual A 14 53722...
Страница 254: ...Cut Along the Dotted Line...
Страница 256: ......
Страница 257: ......