AC POWER/F 2A T 250V (2)
"
LEGEND:
F = Fuse
2A = Current Rating: 2 Ampères
T = Speed: Time Delay (Slow-Blow)
L = Breaking Capacity: Low (Glass)
250V = Voltage Rating
(2) = Fuses used: 2 (two)
Caution:
Before testing fuses, remove AC power by disconnecting the AC power
cord.
Note:
In the event that the unit does not power up with AC power, these fuses
should be tested.
1.10.2 GNSS Receiver
Model
: u-blox M8T
Compatible signals
:
GPS L1 C/A Code transmissions at 1575.42 MHz
GLONASS L1 0F transmissions centered at 1602.0 MHz
Galileo E1 B/C transmissions at 1575.42 MHz
BeiDou B1 transmissions centered at 1561.098 MHz
QZSS L1-SAIF transmissions at 1575.42 MHz
Satellites tracked
: Up to 72 simultaneously
Update rate
: up to 2Hz (concurrent)
Acquisition time
: Typically < 27 seconds from cold start
Antenna requirements
: Active antenna module, +5V, powered by NetClock, 16 dB gain min
imum
Antenna connector
: Type N, female
1.10.3 RS-232 Serial Port (Front Panel)
Function
: Accepts commands to locally configure the IP network parameters via CLI for initial
unit configuration.
Connector
: DB9 F, pin assignments conform to EIA/TIA-574, data communication equipment
20
CHAPTER
1
•
NetClock User Reference Guide
Rev.
16
1.10 Specifications
Содержание NetClock 9400 Series
Страница 2: ......
Страница 4: ...Blank page II NetClock User Reference Guide...
Страница 16: ...BLANK PAGE XIV NetClock User Reference Guide TABLE OF CONTENTS...
Страница 42: ...BLANK PAGE 1 11 Regulatory Compliance 26 CHAPTER 1 NetClock User Reference Guide Rev 16...
Страница 160: ...BLANK PAGE 2 17 Configuring Outputs 144 CHAPTER 2 NetClock User Reference Guide Rev 16...
Страница 238: ...BLANK PAGE 3 5 Managing the Oscillator 222 CHAPTER 3 NetClock User Reference Guide Rev 16...
Страница 462: ...BLANK PAGE 446 NetClock User Reference Guide...