![Spectracom NetClock 9400 Series Скачать руководство пользователя страница 178](http://html1.mh-extra.com/html/spectracom/netclock-9400-series/netclock-9400-series_user-reference-manual_1343619178.webp)
order you assign to your available references typically is a function of their accuracy and reli
ability.
Note:
The References shown on your screen may look different from the ones in
the illustration below, depending on your NetClock 9400 Series Time Server
model and hardware configuration.
Each available type of
Time
and
1PPS
input reference is assigned a human-readable name or
“title” that is used in the
Reference Priority
table, indicating the type of reference. The reference
titles are listed in the following table:
Table 3-1:
Reference priority titles
Title
Reference
ASCII Timecode
ASCII serial timecode input
External 1PPS input
External 1PPS input
Frequency
External Frequency input
GNSS
GNSS input
PTP
PTP input
IRIG
IRIG timecode input
Local System
Built-in clock OR internal 1PPS generation
NTP
NTP input
User
Host (time is manually set by the user)
HAVEQUICK
HAVEQUICK input
The number displayed indicates the number of feature inputs of that type presently installed in
the NetClock– starting with “0” representing the first feature input. For example:
162
CHAPTER
3
•
NetClock User Reference Guide
Rev.
16
3.3 Managing Input References
Содержание NetClock 9400 Series
Страница 2: ......
Страница 4: ...Blank page II NetClock User Reference Guide...
Страница 16: ...BLANK PAGE XIV NetClock User Reference Guide TABLE OF CONTENTS...
Страница 42: ...BLANK PAGE 1 11 Regulatory Compliance 26 CHAPTER 1 NetClock User Reference Guide Rev 16...
Страница 160: ...BLANK PAGE 2 17 Configuring Outputs 144 CHAPTER 2 NetClock User Reference Guide Rev 16...
Страница 238: ...BLANK PAGE 3 5 Managing the Oscillator 222 CHAPTER 3 NetClock User Reference Guide Rev 16...
Страница 462: ...BLANK PAGE 446 NetClock User Reference Guide...