Should, however, the above-mentioned higher threshold value no longer be exceeded, the unit
will remain in the 1200-second flywheel mode until either (a) the lower threshold value is no
longer exceeded, or (b) the 1200-second flywheel period expires. In both cases the PPS status
light will turn green again.
Smart reference monitoring is OFF by default. To turn it ON:
1.
Navigate to
MANAGEMENT > OTHER: Disciplining
.
2.
In the
Status
panel on the left, click the GEAR icon. The
Oscillator Settings
window will
open.
3.
Check the box next to
1PPS Phase Validation
and click Submit.
4.5.1.6
Ethernet Monitoring
To monitor Ethernet status and traffic:
1.
Navigate to
TOOLS > SYSTEM: Ethernet Monitor
. The Ethernet monitoring screen opens: