Web UI Page loc
ation
Current Status
Indication
Troubleshooting
HOME page, Sys
tem Status panel,
Power row
AC and/or DC indicator is
red instead of greenNOTE:
The AC indicator will only
display on the HOME
screen if NetClock is
equipped with an AC
power input.The DC indic
ator will only display on
the HOME screen if NetC
lock is equipped with a DC
power input.
Specified AC
and/or DC input
power is not
present.
Refer to Section
"Connecting Sup
ply Power" on page 36
for AC and
DC power connection information:
If AC indicator is red:
1. Verify AC power cord is connected
to an AC outlet.
2. Verify AC power input switch is ON.
3. Check the two fuses in the AC
power module.
If DC indicator is red:
1. Verify DC power source is within
range specified at the DC power con
nector.
2. Verify DC power is present at the
input connector.
3. Verify DC input polarity.
MANAGEMENT/
NTP Setup page
NTP Status Sum
mary panel
Stratum row
Stratum 15
NTP is not syn
chronized to its
available input
references
(NetClock may
have been in
Holdover mode,
but Holdover
has since
expired without
the return of
valid inputs)
Note: If NetClock was just recently
powered-up or rebooted and input ref
erences are applied, no troubleshoot
ing may be necessary. Allow at least
10-20 minutes for the input references
to be declared valid and NTP to align
to the System Time (allow an addi
tional 35-40 minutes for a new install
with GNSS input).
1. Verify in the Configure Reference Pri
orities table that all available ref
erences enabled. See
"Configuring
Input Reference Priorities" on
page 163
.
2. Verify that the Reference Status on
the HOME page shows “OK” (Green)
for all available references.
3. Verify NTP is enabled and con
figured correctly. See
"NTP Refer
ence Configuration" on
page 103
.
NetClock User Reference Guide
329
APPENDIX
Содержание NetClock 9400 Series
Страница 2: ......
Страница 4: ...Blank page II NetClock User Reference Guide...
Страница 16: ...BLANK PAGE XIV NetClock User Reference Guide TABLE OF CONTENTS...
Страница 42: ...BLANK PAGE 1 11 Regulatory Compliance 26 CHAPTER 1 NetClock User Reference Guide Rev 16...
Страница 160: ...BLANK PAGE 2 17 Configuring Outputs 144 CHAPTER 2 NetClock User Reference Guide Rev 16...
Страница 238: ...BLANK PAGE 3 5 Managing the Oscillator 222 CHAPTER 3 NetClock User Reference Guide Rev 16...
Страница 462: ...BLANK PAGE 446 NetClock User Reference Guide...