IRIG 0 = 1
st
IRIG input instance
Frequency 1 = 2nd frequency input instance
NTP 2 = 3rd NTP input instance
The columns of the
Reference Priority
table are defined as follows:
Priority
—Defines the order or priority for each index (row). The range is 1 to 16, with 1
being the highest priority and 16 being the lowest priority. The highest priority ref
erence that is available and valid is the reference that is selected.
Time
—The reference selected to provide the necessary “Time” reference.
1PPS
—The reference selected to provide the necessary “1PPS” reference.
Enabled
—The reference is enabled.
Delete
—Removes the Index (row) from the Reference Priority table.
3.3.1.1
Configuring Input Reference Priorities
NetClock can use numerous external time sources, referred to as "references". As external time
sources may be subject to different degrees of accuracy and reliability, you can determine in
which order (= priority) NetClock calls upon its external time and 1PPS references.
For additional information, see also "Input Reference Priorities" on page 161.
Accessing the Reference Priority Screen
To access the
Reference Priority Setup
screen:
1.
Navigate to
MANAGEMENT > OTHER: Reference Priority
.
OR:
1.
On the
HOME
screen, click the GEAR icon in the
Reference Status
panel:
2.
The
Configure Reference Priorities
screen will display.
3.3 Managing Input References
CHAPTER
3
•
NetClock User Reference Guide
Rev.
16
163
Содержание NetClock 9400 Series
Страница 2: ......
Страница 4: ...Blank page II NetClock User Reference Guide...
Страница 16: ...BLANK PAGE XIV NetClock User Reference Guide TABLE OF CONTENTS...
Страница 42: ...BLANK PAGE 1 11 Regulatory Compliance 26 CHAPTER 1 NetClock User Reference Guide Rev 16...
Страница 160: ...BLANK PAGE 2 17 Configuring Outputs 144 CHAPTER 2 NetClock User Reference Guide Rev 16...
Страница 238: ...BLANK PAGE 3 5 Managing the Oscillator 222 CHAPTER 3 NetClock User Reference Guide Rev 16...
Страница 462: ...BLANK PAGE 446 NetClock User Reference Guide...