Navigate to
Management
>
Disciplining
, and click the GEAR icon in the top-right corner
of the
Status
panel.
14.
Set the value
Maximum TFOM for Sync
to 4 (this will make NetClock to go out of sync if
the phase error is greater than 1μs).
15.
Set the value for
Holdover Timeout
to 10 s, to allow NetClock to exit holdover quickly.
16.
Leave the
Phase Error Limit
at 0, and do not check any of the checkboxes (or, for more
information, see "Configuring the Oscillator" on page 215).
2.15.12.4 Configuring NTP over Anycast (BGP)
To configure
NTP over Anycast
, using
BGP
(Border Gateway Protocol):
1.
Confirm that your existing network infrastructure is Anycast capable, and uses BGP.
Determine the network specifics, such as your Autonomous System (AS) number, Neigh
bor’s address and Neighbor’s AS number.
2.
In the NetClock Web UI, navigate to
MANAGEMENT > Network > NTP Setup.
3.
In the
Actions Panel
, click
NTP over Anycast
.
4.
In the
NTP Anycast
window, select the
General
tab.
5.
On the
General
tab, select your desired IP Version. This selection automatically com
municates with the
BGP
tab and displays the neighbor address field based on your
needs.
6.
Select the port to associate the Anycast service with (depending on the option card con
figuration of your unit, there may be only ETH0 available). If you desire IPv6 func
tionality, you must also select the IPv6 port address since there may be multiple IPv6
addresses on a single port.
7.
In the
NTP Anycast
window, navigate to the
BGP
tab.
8.
On the
BGP
tab, check
Enable
.
9.
Input your
AS number
.
10.
Input the neighbor's address.
11.
Input the neighbor's AS number.
12.
Click
Submit
.
13.
Select the port address to associate the Anycast service with (because there may be mul
tiple addresses on a single port), and click Submit. If no addresses appear, an IP
address must be added to the port (see "Network Ports" on page 59).
14.
Next, specify the maximum
TFOM Setting
(Time Figure of Merit), and the
Holdover
Timeout
value. These two parameters determine NetClock's accuracy "tolerance win
dow": A small window will cause NetClock to deliver a more accurate time window, but
also will cause it to quickly withdraw from the Anycast server pool, i.e. declare itself an
invalid reference. (For more information about TFOM, see "Configuring the Oscillator"
2.15 Configuring NTP
CHAPTER
2
•
NetClock User Reference Guide
Rev.
16
127
Содержание NetClock 9400 Series
Страница 2: ......
Страница 4: ...Blank page II NetClock User Reference Guide...
Страница 16: ...BLANK PAGE XIV NetClock User Reference Guide TABLE OF CONTENTS...
Страница 42: ...BLANK PAGE 1 11 Regulatory Compliance 26 CHAPTER 1 NetClock User Reference Guide Rev 16...
Страница 160: ...BLANK PAGE 2 17 Configuring Outputs 144 CHAPTER 2 NetClock User Reference Guide Rev 16...
Страница 238: ...BLANK PAGE 3 5 Managing the Oscillator 222 CHAPTER 3 NetClock User Reference Guide Rev 16...
Страница 462: ...BLANK PAGE 446 NetClock User Reference Guide...