Note:
TIP:
If synchronization to UTC is NOT required, it is advisable to set a time
in the past or future, so as to avoid users inadvertently considering the distributed
time to be genuine.
Caution:
Note that this mode of operation is intended for special use cases e.g.,
autonomous systems, where legally traceable time is not required: This time will
be inaccurate/not traceable, since it is not tied to any reference.
To hand-set the System Time, and configure this time to be a valid reference:
1.
Navigate to
MANAGEMENT > OTHER: Time Management
.
2.
In the
System Time
panel on the left, click the GEAR icon.
3.
Select
Manual Time Set
. Set your time & date, as needed:
System Time
[DATE; TIME]: If you do not select
Set Year Only
, this box will show
the current time in the format:
Year-Month-Day Hour:Minute:Second
.
To set the time manually, click anywhere in the
System Time
field. A drop-down
calendar with time-setting sliders will appear:
The time in the
System Time
field will default to the current date and time. To set
the time, use the sliders. The time will display between the calendar and the
sliders, and also next to the chosen date in the field directly above the calendar.
To close the calendar, click anywhere in the
Edit System Time
window.
NOTE: Except for testing purposes, you should not choose a date other than the
current day.
Set Year Only
: Some legacy time formats (e.g., IRIG) do not support years. Check
ing this box will open a data entry field to manually set the year. Spectracom
3.2 System Time
CHAPTER
3
•
NetClock User Reference Guide
Rev.
16
151
Содержание NetClock 9400 Series
Страница 2: ......
Страница 4: ...Blank page II NetClock User Reference Guide...
Страница 16: ...BLANK PAGE XIV NetClock User Reference Guide TABLE OF CONTENTS...
Страница 42: ...BLANK PAGE 1 11 Regulatory Compliance 26 CHAPTER 1 NetClock User Reference Guide Rev 16...
Страница 160: ...BLANK PAGE 2 17 Configuring Outputs 144 CHAPTER 2 NetClock User Reference Guide Rev 16...
Страница 238: ...BLANK PAGE 3 5 Managing the Oscillator 222 CHAPTER 3 NetClock User Reference Guide Rev 16...
Страница 462: ...BLANK PAGE 446 NetClock User Reference Guide...