4.
Upon initial login, you will be asked to register your product. Spectracom recommends
to register NetClock, so as to receive software updates and services notices. See also
"Product Registration" on page 265.
Number of login attempts
The number of failed login attempts for ssh is hard-set to (4) four. This value is not configurable.
The number of failed login attempts for the Web UI (HTTP/HTTPS) is hard-set to (5) five failed
login attempts, with a 60 second lock. These two values are not configurable.
To continue with the configuration, see e.g., "The Web UI HOME Screen" on page 15.
To learn more about setting up different types of user accounts, see "Managing User Accounts"
on page 235.
2.13
Connecting Reference Inputs and Network Interface
NetClock 9400 can synchronize to various external inputs (such as GPS, NTP, PTP, and/or a
user set time). Depending on the desired operation and specific NetClock configuration, con
nect the GPS, or other external references (NTP input reference and “user set time” are software
configurations that require no additional physical connection to NetClock. These two reference
inputs are discussed later in this manual).
1.
GPS Reference input
: Typical installations include GPS as an external reference input. If
the GPS receiver is not installed or if the GPS will not be used as a NetClock reference,
just disregard the steps to install the GPS antenna and associated cabling.
Install the GPS antenna, surge suppressor, antenna cabling, and GPS preamplifier (if
required). Refer to the documentation included with the Model 8225 GPS antenna for
additional information regarding GPS antenna installation.
Connect the GPS cable to the rear panel antenna input jack (refer to LINK). Until the GPS
antenna is connected to the rear panel jack, the Antenna Problem alarm is asserted, caus
ing the front panel “Fault” light to be blinking orange (the Antenna Problem alarm indic
ates an open or short exists in the antenna cable). Unless there is an open or short in the
antenna cable, the Fault light should stop flashing orange once the GPS antenna and
coax cable are connected to the rear panel. If the Fault light does not stop flashing after
connecting the antenna, see LINK GPS troubleshooting reception issues
2.
PTP Reference input
: With the available PTP option card configured as a slave syn
chronizing via Ethernet/RJ-45 to a PTP master.
3.
Network interface to LAN
: Obtain the following network information from your network
administrator before continuing:
2.13 Connecting Reference Inputs and Network Interface
CHAPTER
2
•
NetClock User Reference Guide
Rev.
16
55
Содержание NetClock 9400 Series
Страница 2: ......
Страница 4: ...Blank page II NetClock User Reference Guide...
Страница 16: ...BLANK PAGE XIV NetClock User Reference Guide TABLE OF CONTENTS...
Страница 42: ...BLANK PAGE 1 11 Regulatory Compliance 26 CHAPTER 1 NetClock User Reference Guide Rev 16...
Страница 160: ...BLANK PAGE 2 17 Configuring Outputs 144 CHAPTER 2 NetClock User Reference Guide Rev 16...
Страница 238: ...BLANK PAGE 3 5 Managing the Oscillator 222 CHAPTER 3 NetClock User Reference Guide Rev 16...
Страница 462: ...BLANK PAGE 446 NetClock User Reference Guide...