HiTemp140-M12

HiTemp140-M12

High Temperature Data Logger with an M12 Probe Connector

Содержание HiTemp140-M12

Страница 1: ...To view the full MadgeTech product line visit our website at www madgetech com Product User Guide HiTemp140 M12 HiTemp140 M12 High Temperature Data Logger with an M12 Probe Connector ...

Страница 2: ...line visit our website at www madgetech com HiTemp140 M12 Data Logger Product Overview 2 Installation Guide 3 Device Operation 3 Wiring the Data Logger 4 Probe Connection 4 Product Maintenance 5 RMA Instructions 5 General Specifications 6 Table of Contents ...

Страница 3: ...ote Specific M12 wiring configuration is required for compatibility see page 4 Submergibility The HiTemp140 M12 logger itself is rated IP40 and not submersible It will inherit the IP rating of the probe it is attached to allowing for potential submergibility depending upon the probe O Rings O ring maintenance is a key factor when properly caring for the HiTemp140 M12 The O rings ensure a tight sea...

Страница 4: ...e for the data logging application and click Start Quick Start applies the most recent custom start options Batch Start is used for managing multiple loggers at once Real Time Start stores the dataset as it records while connected to the logger The status of the device will change to Running Waiting to Start or Waiting to Manual Start depending upon your start method Disconnect the data logger fro...

Страница 5: ... attached to up to and including IP68 IP69K Probe Connection Connecting probes to the HiTemp140 M12 Materials 15 mm wrench Compatible Probe with M12 Connector 1 Connect the probe to the data logger using the wiring diagram above 2 Use a 15 mm hex wrench to tighten the threads and secure the probe to the data logger The HiTemp140 M12 is compatible with probes that have the wiring configuration as s...

Страница 6: ...ce signed in click on the Make New RMA button and fill in all the blank fields 3 Complete the applicable fields on the form including customer Billing and Shipping information even if they are the same Please see the field explanation below for a more detailed description about questions asked in the Device Information section 4 When all of the fields are complete click Generate RMA 5 Print out th...

Страница 7: ...ammed into the device to restrict access to configuration options Data may be read out without the password Memory Wrap Around Yes Battery Type 3 6V high temperature lithium battery included user replaceable Battery Life 1 year typical 1 minute reading rate Calibration Digital calibration through software Calibration Date Automatically recorded within device Data Format Date and time stamped C F R...

Страница 8: ...MadgeTech Inc 6 Warner Road l Warner NH 03278 Phone 603 456 2011 l Fax 603 456 2012 www madgetech com l info madgetech com DOC 1312036 00 REV 2 01 22 2018 ...