ALARM 01:
.../.../... A...
ALARM 02:
.../.../... A...
ESC TO EXIT
˄˅
MACHINE INFO
LATEST ALARMS
ALARM STATISTIC
MAINTENANCE LIST
PRESS ENTER
˄˅
N. POWER ALARMS
1
N. FILTER ALARMS
0
ESC TO EXIT
˄˅
Sequential list of the latest 16 alarms
stored by the control computer reporting
their display date.
For coding refer to the table below.
9
ALARM coding table
All these alarm types imply to make reference to the Technical Service of Sistem Air
Alarm statistic:
this menu displays the
total number of alarms divided by type.
Press
Enter
to access the menu.
Use the
up
and
down
arrows to move
onto the next screen display. Press
ESC
to go back to the previous menu.
1
Power alarm:
it indicates how many ti-
mes the machine was electrically turned
on and off.
Filter Alarm:
it indicates how many
times the manual fi lter cleaning was
required.
2
CODE
MEANING
DESCRIPTION
INTERVENTION PROCEDURE
A00
Data
The control board detects an incongruity between
the stored data and the check-sum
Call the Technical Service
AXX-01
Overextention
Inverter: bus upper tension limit exceeded
Extend deceleration time
AXX-02
Under power
Inverter: bus lower tension limit exceeded
Check supply tension
AXX-03
Temperature
Inverter: bus temperature limit exceeded
Check inverter ventilation
AXX-04
Overcharge
Inverter: high-limit of logical current exceeded
Extend acceleration time and/or decrease
vacuum set point
AXX-06
Current
Inverter: high-limit of physical current exceeded
Decrease vacuum set point
AXX-07
Motion ART data
Inverter: an incongruity between data and the
check-sum is found
Call the Technical Service
AXX-10
Flash
Inverter: incorrect physical access to the data
Call the Technical Service
AXX-16
Serial communication
Inverter: communication with control board
interrupted
Call the Technical Service
AXX-98
Serial communication
Wrong connection between the electronic board
and the inverter
Check the patch cable used for the
serial connection
A09
Filter alarm
Filter cartridge is dirty
Clean fi lter cartridge
A10
Dust alarm
Dust container is full
Empty dust container
A11/A12
Maintenance alarm
Supplementary maintenance required
Call the Technical Service
A13
Transducer alarm
Transducer does not communicate with control
board
Call the Technical Service
A14
Pressure switch alarm
Autocleaner system is not working
Call the Technical Service
Содержание Industrial Clean Basic
Страница 2: ......
Страница 76: ...Manuale istruzioni Industrial Clean 74 15 02 12 Rev 1 0 0 LINGUA ORIGINALE...
Страница 152: ...Industrial Clean instruction manual 74 15 02 12 Rev 1 0 0...
Страница 223: ...69 3 15 02 12 Rev 1 0 0 Fran ais Replacer le bac poussi res 6 Baisser la poign e de verrouillage des deux mains 7...
Страница 228: ...Manuel d utilisation Industrial Clean 74 15 02 12 Rev 1 0 0...
Страница 299: ...69 4 15 02 12 Rev 1 0 0 Deutsch Staubbeh lter wieder einsetzen 6 Mit beiden H nden den Verschlusshebel herunterdr cken 7...
Страница 304: ...Bedienungsanleitung Industrial Clean 74 15 02 12 Rev 1 0 0...
Страница 380: ...Manual de instrucciones Industrial Clean 74 15 02 12 Rev 1 0 0...
Страница 383: ......