17 - TROUBLESHOOTING
PROBLEM
CAUSE
SOLUTION
There is no suction from any of the
suction sockets
Alarm signalled on the
computer
RESET the alarm and carry out
recommended maintenance
Remove and plug in the fl exible
hose to start suction (connect
the power cable)
The power cable is unplugged Connect the power cable
The micro line 1 and 2 cables
are not connected
Connect the activation cable
(sensor)
There is no air suction from just one
suction socket
The electric contacts are
interrupted or the micro
switch of suction socket is out
of order
Call Technical Service
The air suction is weak
More than one socket is being
used at the same time
Reduce the number of sockets
used at the same time
The fl exible hose or the
accessories are broken
Check the fl exible hose
and the accessory are not
damaged (replace them if
needed)
Filter cartridge is dirty
Clean the fi lter cartridge
The gasket of the dust bin is
damaged
Check integrity
Obstruction of the piping net
Call Technical Service
The air exhaust is clogged
Call Technical Service
Dust container is full
Empty dust container
Inverter alarm
Call Technical Service
The vacuum cleaner still works even if
the suction inlets are closed
Malfunctioning of the
electronic board
Call Technical Service
Содержание Industrial Clean Basic
Страница 2: ......
Страница 76: ...Manuale istruzioni Industrial Clean 74 15 02 12 Rev 1 0 0 LINGUA ORIGINALE...
Страница 152: ...Industrial Clean instruction manual 74 15 02 12 Rev 1 0 0...
Страница 223: ...69 3 15 02 12 Rev 1 0 0 Fran ais Replacer le bac poussi res 6 Baisser la poign e de verrouillage des deux mains 7...
Страница 228: ...Manuel d utilisation Industrial Clean 74 15 02 12 Rev 1 0 0...
Страница 299: ...69 4 15 02 12 Rev 1 0 0 Deutsch Staubbeh lter wieder einsetzen 6 Mit beiden H nden den Verschlusshebel herunterdr cken 7...
Страница 304: ...Bedienungsanleitung Industrial Clean 74 15 02 12 Rev 1 0 0...
Страница 380: ...Manual de instrucciones Industrial Clean 74 15 02 12 Rev 1 0 0...
Страница 383: ......