05.2006
Parameterizing Steps
Siemens AG
6SE7087-2JD60
SIMOVERT MASTERDRIVES
Operating Instructions
9-17
Type 1PH610 1PH613 1PH616 1PH618 1PH620
1PH622
T1
in
s 1500 1800 2100 2400 2400 2400
Exceptions: 1PH610 at n = 1150 rpm: T1 = 1200 n
Shaft height
100
132
160
180
225
T1 in s
1500
1800
2100
2400
2400
Type
1PH7284 1PH7286 1PH7288
T1 in s
4500
5000
5400
Shaft height
180
225
T1 in s
1800
1800
Type 1PL6284
1PH6286
1PH6288
T1 in s
3200
3900
4300
Shaft height
100
132
160
T1 in s
1500
1800
2100
If 1PH7, 1PL6, or 1PH4 motors are parameterized in the list selection
(P097), both the motor cooling (P382) and the thermal motor time
constant (P383) are assigned the correct default values.
1LG6 motors
Type
2-
pole
4-
pole
6-
pole
8-
pole
183 1800
1800
- -
186
-
1800
2700
2100
206
1800 - 2700 -
207
1800 2700 2700 2700
220
- 2400
- 2700
223
2400 2700 3300 2400
253
2700 3000 2700 3000
280
2400 3300 3000 3600
283
2400 3000 3600 3900
310
2700 3300 3600 3900
313
2700 3900 3600 4200
316
2700 3900 4200 4200
317
2700 3900 4500 3900
318
3600 3900 4500 5700
1PH6 motors
1PA6 motors
(= 1PH7 motors)
1PL6 motors
1PH4 motors
NOTE