05.2006
Technical Data
Siemens AG
6SE7087-2JD60
SIMOVERT MASTERDRIVES
Operating Instructions
13-5
Designation
Value
Order No.
6SE70... 21-1CA60
21-3CA60
21-8CB60
22-3CB60
23-2CB60 24-4CC60
Rated voltage
[V]
•
Input
•
Output
3 AC 200 (- 10 %) to 230 (+ 15 %)
3 AC 0 up to rated input voltage
Rated frequency
[Hz]
•
Input
•
Output:
V/f = constant
V = constant
50 / 60
±
6 %
0 to 600
8 to 300
Rated current
[A]
•
Input
•
Output
11.7
10.6
14.6
13.3
19.5
17.7
25.2
22.9
35.4
32.2
48.6
44.2
DC link voltage
[V]
270 (- 10 %) to 310 (+ 15 %)
Rated output
[kVA] 3.7 to 4.2
4.7 to 5.2
6.0 to 6.9
8.0 to 9.1
11.2 to 12.8
15.4 to 17.6
Auxiliary current supply
[V]
DC 24 (20 - 30)
•
Max. aux. curr. requirement[A]
Standard version at 20 V
1.5
•
Max. aux. curr. requirement[A]
Maximum version at 20 V
2.5
Pulse frequency
[kHz]
1.5 to 16 (see Fig. „Derating curves“)
Load class II to EN 60 146-1-1
Base load current
[A]
0.91 x rated output current
Base load duration
[s]
240
Overload current
[A]
1.36 x rated output current
Overload duration
[s]
60
Load class II to EN 60 146-1-1 (additional)
Base load current
[A]
0.91 x rated output current
Base load duration
[s]
270
Overload current
[A]
1.6 x rated output current
Overload duration
[s]
30
Losses, cooling, power factor
Power factor
•
Line cos
ϕ
1L
•
Converter cos
ϕ
C
≥
0.98
< 0.92 ind.
Efficiency
η
(rated operation)
≥
0.97
Power loss
(at 2.5 kHz)
[kW]
0.13
0.16
0.20 0.25 0.32 0.41
Cooling-air requirement [m³/s]
0.009 0.009 0.022 0.022 0.022 0.028
Pressure drop
∆
p
[Pa]
10 10 32 32 32 30
Sound pressure levels, types of construction, dimensions, weights
Sound
pressure
level
[dB(A)]
60 60 60 60 60 60
Type
of
construction
A A B B B C
Dimensions [mm]
•
Width
•
Height
•
Depth
90
425
350
90
425
350
135
425
350
135
425
350
135
425
350
180
600
350
Weight approx.
[kg]
8.5 8.5 12.5
12.5 12.5 21
Table 13-3
Air-cooled converter (part 1)