Parameterizing Steps
05.2006
6SE7087-2JD60 Siemens
AG
9-58
Operating Instructions
SIMOVERT MASTERDRIVES
P462 = ?
Enter the acceleration time from standstill up to reference
frequency (P352)
P463 = ?
Enter the unit for acceleration time P462
0 = Seconds
1 = Minutes
2 = Hours
P464 = ?
Enter the deceleration time from reference frequency
(P352) up to standstill
P465 = ?
Enter the unit for deceleration time P464
0 = Seconds
1 = Minutes
2 = Hours
no
yes
P115 = 2
Sinusoidal filter (P068=1)
or
synchronous motor?
Calculate motor model "Motor identification at standstill"
NOTICE:
Current flows through the motor and the rotor rotates!
After pressing the "P" key, the alarm message "A087" appears.
The converter must be turned on within 20 secs!
Analog tachometer?
no
yes
Adjust
tachometer
Adjust tachometer
Tachometer to ATI: See operating instructions for ATI
Tachometer to terminal strip: See function diagrams for analog
inputs
Analog tachometer present?