Parameterizing Steps
05.2006
6SE7087-2JD60 Siemens
AG
9-42
Operating Instructions
SIMOVERT MASTERDRIVES
9.3 Motor
list
Input in
P097
Motor order
number
(MPRD)
Rated
speed
nn [rpm]
Frequency
fn [Hz]
Current
In [A]
Voltage
Un [V]
Torque
Mn [Nm]
cos
ϕ
i
µ
[%]
1 1PH7101-2_F_ 1750 60.0 9.7 398
23.5 0.748
58.3
2 1PH7103-2_D_ 1150 40.6 9.7 391
35.7 0.809
51.8
3 1PH7103-2_F_ 1750 60.95
12.8 398
34 0.835
41.3
4 1PH7103-2_G_ 2300 78.8 16.3 388
31 0.791
50.4
5 1PH7105-2_F_ 1750 60.0 17.2 398
43.7 0.773
54.1
6 1PH7107-2_D_ 1150 40.3 17.1 360
59.8 0.807
51.4
7 1PH7107-2_F 1750 60.3
21.7 381
54.6 0.802
48.8
8 1PH7131-2_F_ 1750 59.65
23.7 398
71 0.883
34.2
9 1PH7133-2_D_ 1150 39.7 27.5 381
112 0.853
46.2
10 1PH7133-2_F_ 1750 59.65 33.1 398
95.5 0.854
41.1
11 1PH7133-2_G_ 2300
78.0 42.4 398
93
0.858
40.4
12 1PH7135-2_F_ 1750 59.45 40.1 398
117 0.862
40.3
13 1PH7137-2_D_ 1150
39.6 40.6 367
162 0.855
45.8
14 1PH7137-2_F_ 1750
59.5 53.1 357
136 0.848
43.0
15 1PH7137-2_G_ 2300
77.8 54.1 398
120 0.866
39.3
16 1PH7163-2_B_ 400
14.3 28.2 274
227 0.877
40.4
17 1PH7163-2_D_ 1150 39.15 52.2 364
208 0.841
48.7
18 1PH7163-2_F_ 1750
59.2 69.0 364
185 0.855
41.2
19 1PH7163-2_G_ 2300
77.3 78.5 398
158 0.781
55.3
20 1PH7167-2_B_ 400
14.3 35.6 294
310 0.881
39.0
21 1PH7167-2_D_ 1150
39.1 66.4 357
257 0.831
50.9
22 1PH7167-2_F_ 1750 59.15 75.2 398
224 0.860
40.3
23 1PH7184-2_B_ 400
14.2 49.5 271
390 0.840
52.5
24 1PH7184-2_D_ 1150
39.1 87.5 383
366 0.820
48.0
25 1PH7184-2_F_ 1750
59.0 120.0 388
327 0.780
52.9
26 1PH7184-2_L_ 2900
97.4 158.0 395
267 0.800
48.7
27 1PH7186-2_B_ 400
14.0 67.0 268
505 0.810
58.3
28 1PH7186-2_D_ 1150
39.0 116.0 390
482 0.800
50.4
29 1PH7186-2_F_ 1750
59.0 169.0 385
465 0.800
50.0
30 1PH7186-2_L_ 2900
97.3 206.0 385
333 0.780
52.0
31 1PH7224-2_B_ 400
14.0 88.0 268
725 0.870
41.5
32 1PH7224-2_D_ 1150
38.9 160.0 385
670 0.810
49.4
33 1PH7224-2_U_ 1750
58.9 203.0 395
600 0.840
43.4
Asynchronous
motors 1PH7(=PA6) /
1PL6 / 1PH4