Parameterizing Steps
05.2006
6SE7087-2JD60 Siemens
AG
9-44
Operating Instructions
SIMOVERT MASTERDRIVES
Input in
P097
Motor order
number
(MPRD)
Rated
speed
nn [rpm]
Frequency
fn [Hz]
Current
In [A]
Voltage
Un [V]
Torque
Mn [Nm]
cos
ϕ
i
µ
[%]
71 1PH4168-4_F_ 1750
59.4 117.0 400
333 0.82
36.8
72 1PH7107-2_G_ 2300
78.6 24.8 398
50
0.80 48.8
73 1PH7167-2_G_ 2300
77.4 85.0 398
183
0.84 47.1
74 1PH7284-_
_B_ 500
17.0 144.0 400
1529 0.87 41.7
75 1PH7284-_
_D_ 1150
38.6 314.0 400
1414 0.82 50.3
76 1PH7284-_
_F_ 1750
58.7 393.0 400
1228 0.86 41.5
77 1PH7286-_
_B_ 500
17.0 180.0 400
1909 0.86 43.3
78 1PH7286-_
_D_ 1150
38.6 414.0 380
1745 0.81 52.7
79 1PH7286-_
_F_ 1750
58.7 466.0 400
1474 0.87 39.5
80 1PH7288-_
_B_ 500
17.0 233.0 400
2481 0.87 42.6
81 1PH7288-_
_D_ 1150
38.6 497.0 385
2160 0.82 50.7
82 1PH7288-_
_F_ 1750
58.7 586.0 400
1856 0.87 39.9
83 to 99
for future applications
100 1PL6284-_
_D_ 1150
38.9 478.0 400
2325
0.89 32.6
101 1PL6284-_
_F_ 1750
59.0 616.0 400
2019
0.90 26.3
102 1PL6286-_
_D_ 1150
38.9 637.0 380
2944
0.89 33.6
103 1PL6286-_
_F_ 1750
59.0 736.0 400
2429
0.91 24.7
104 1PL6288-_
_D_ 1150
38.9 765.0 385
3607
0.89 32.4
105 1PL6288-_
_F_ 1750
59.0 924.0 400
3055
0.91 25.1
106 to
127
for future applications
Table 8
Motor list 1PH7 (=1PA6) / 1PL6 / 1PH4