Technical Data
05.2006
6SE7087-2JD60 Siemens
AG
13-8
Operating Instructions
SIMOVERT MASTERDRIVES
Designation
Value
Order No.
6SE70... 23-4EC61
23-8ED61
24-7ED61
26-0ED61
27-2ED61
Rated voltage
[V]
•
Input
•
Output
3 AC 380 (- 15 %) to 480 (+ 10 %)
3 AC 0 up to rated input voltage
Rated frequency
[Hz]
•
Input
•
Output:
V/f = constant
V = constant
50 / 60
±
6 %
0 to 600
8 to 300
Rated current
[A]
•
Input
•
Output
37.4
34.0
41.3
37.5
51.7
47.0
64.9
59.0
79.2
72.0
DC link voltage
[V]
510 (- 15 %) to 650 (+ 10 %)
Rated output
[kVA]
22.4 to
28.2
24.7 to
31.1
31.0 to
39.0
38.9 to
49.0
47.4 to
59.8
Auxiliary current supply
[V]
DC 24 (20 - 30)
•
Max. aux. curr. requirement[A]
Standard version at 20 V
1.5
•
Max. aux. curr. requirement[A]
Maximum version at 20 V
2.5
Pulse frequency
[kHz]
1.5 to 16 (see Fig. „Derating curves“)
Load class II to EN 60 146-1-1
Base load current
[A]
0.91 x rated output current
Base load duration
[s]
240
Overload current
[A]
1.36 x rated output current
Overload duration
[s]
60
Load class II to EN 60 146-1-1 (additional)
Base load current
[A]
0.91 x rated output current
Base load duration
[s]
270
Overload current
[A]
1.6 x rated output current
Overload duration
[s]
30
Losses, cooling, power factor
Power factor
•
Line cos
ϕ
1L
•
Converter cos
ϕ
C
≥
0.98
< 0.92 ind.
Efficiency
η
(rated operation)
≥
0.98
≥
0.97
≥
0.98
Power loss
(at 2.5 kHz)
[kW]
0.49 0.58 0.73 0.86 1.05
Cooling-air requirement [m³/s]
0.028 0.054 0.054 0.054 0.054
Pressure drop
∆
p
[Pa]
30 230 230 230 230
Sound pressure levels, types of construction, dimensions, weights
Sound
pressure
level
[dB(A)]
60 65 65 65 65
Type
of
construction
C D D D D
Dimensions [mm]
•
Width
•
Height
•
Depth
180
600
350
270
600
350
270
600
350
270
600
350
270
600
350
Weight
approx. [kg]
21 32 32 32 32
Table 13-6
Air-cooled converter (part 4)