R1: Reference point approach
15.5 Referencing with incremental measurement systems
Basic Functions
Function Manual, 09/2011, 6FC5397-0BP40-2BA0
1221
The "Position restored" state can only be exited by referencing the axis. As a consequence, IS
DB31, .... DBX71.4/5 ("restored 1/2") is deleted and IS DB31, .... DBX60.4/5 ("referenced/synchronized 1/2") is
set.
Retracting the tool in JOG mode
Once the tool has been retracted in JOG mode, axes whose positions have been restored are referenced. For
further details, see also machine data:
• MD20700 $MC_REFP_NC_START_LOCK (NC start lock without a home position).
• MD34110 $MA_REFP_CYCLE_NR (Axis sequence for channel-specific referencing)
The PLC prompts the display of this state with the output of a corresponding PLC message by evaluating the
above NC/PLC interface signals.
Note
In the case of spindles, the states "Position restored" and "Referenced/Synchronized" can
also be deleted by exceeding the encoder limit frequency.
Note
If machine data MD20700 $MC_REFP_NC_START_LOCK is set to a value of "2", then an
NC start is also possible with "restored" axis positions (in the MDI mode or when
overstoring).
Содержание SINUMERIK 828D Turning
Страница 34: ...Basic Functions 34 Function Manual 09 2011 6FC5397 0BP40 2BA0 ...
Страница 146: ...A3 Axis Monitoring Protection Zones 2 6 Data lists Basic Functions 146 Function Manual 09 2011 6FC5397 0BP40 2BA0 ...
Страница 328: ...F1 Travel to fixed stop 6 5 Data lists Basic Functions 328 Function Manual 09 2011 6FC5397 0BP40 2BA0 ...
Страница 816: ...K2 Axis Types Coordinate Systems Frames 10 9 Data lists Basic Functions 816 Function Manual 09 2011 6FC5397 0BP40 2BA0 ...
Страница 1198: ...P4 PLC for SINUMERIK 828D 14 6 Function interface Basic Functions 1198 Function Manual 09 2011 6FC5397 0BP40 2BA0 ...
Страница 1752: ...Appendix 20 2 Overview Basic Functions 1752 Function Manual 09 2011 6FC5397 0BP40 2BA0 ...
Страница 1774: ...Glossary Basic Functions 1774 Function Manual 09 2011 6FC5397 0BP40 2BA0 ...