A3: Axis Monitoring, Protection Zones
2.3 Protection zones
Basic Functions
Function Manual, 09/2011, 6FC5397-0BP40-2BA0
109
Maximum number of protection areas
The maximum definable number of machine- and channel-related protection zones is set via:
MD18190 $MN_MM_NUM_PROTECT_AREA_NCK (Number of files for machine-related protection zones)
MD28200 $MC_MM_NUM_PROTECT_AREA_CHAN (Number of files for channel-specific protection zones)
Coordinates
The coordinates of a protection zone must always be programmed as absolute values with respect to the
reference point of the protection zone. When the protection zone is activated via the part program it is possible to
apply a relative offset to the reference point of the protection zone.
Examples
In the following figures some examples for protection zones have been presented:
Figure 2-8
Example of application on turning machine
3
:
;
;
=
0
:RUNSLHFHUHODWHG
SURWHFWLRQ]RQHIRU
VSLQGOHFKXFN
:RUNSLHFHUHODWHG
SURWHFWLRQ]RQHIRU
WRROKROGHU
7RROKROGHU
'ULOO
Содержание SINUMERIK 828D Turning
Страница 34: ...Basic Functions 34 Function Manual 09 2011 6FC5397 0BP40 2BA0 ...
Страница 146: ...A3 Axis Monitoring Protection Zones 2 6 Data lists Basic Functions 146 Function Manual 09 2011 6FC5397 0BP40 2BA0 ...
Страница 328: ...F1 Travel to fixed stop 6 5 Data lists Basic Functions 328 Function Manual 09 2011 6FC5397 0BP40 2BA0 ...
Страница 816: ...K2 Axis Types Coordinate Systems Frames 10 9 Data lists Basic Functions 816 Function Manual 09 2011 6FC5397 0BP40 2BA0 ...
Страница 1198: ...P4 PLC for SINUMERIK 828D 14 6 Function interface Basic Functions 1198 Function Manual 09 2011 6FC5397 0BP40 2BA0 ...
Страница 1752: ...Appendix 20 2 Overview Basic Functions 1752 Function Manual 09 2011 6FC5397 0BP40 2BA0 ...
Страница 1774: ...Glossary Basic Functions 1774 Function Manual 09 2011 6FC5397 0BP40 2BA0 ...