K2: Axis Types, Coordinate Systems, Frames
10.3 Zeros and reference points
Basic Functions
708
Function Manual, 09/2011, 6FC5397-0BP40-2BA0
10.3.2
Position of coordinate systems and reference points
Control POWER ON
For incremental measuring probes, the reference point must be approached each time the control is activated so
that the control can transfer all position values to the coordinate system.
Figure 10-7 Position of coordinate systems by machine zero M and workpiece zero W
Figure 10-8 Position of reference point in relation to machine zero
=
0
0
;
0DFKLQH
FRRUGLQDWH
V\VWHP0&6
0DFKLQH
]HUR
6SLQGOH
:RUNSLHFH
OHQJWK
:RUNSLHFH
FRRUGLQDWH
V\VWHP:&6
:RUNSLHFH
]HUR
0DFKLQH
]HUR
5HIHU
HQFH
SRLQW
7RROKROGHU
7RROKROGHUUHIHUHQFHSRLQW
7
/
/
5
=
;
=
0
;