F1: Travel to fixed stop
6.2 General functionality
Basic Functions
Function Manual, 09/2011, 6FC5397-0BP40-2BA0
309
SERUPRO
Block search with calculation, multichannel
The block search in program test mode is designated SERUPRO and is derived from the "Search-Run by
Program test." This search mode allows the user a multichannel block search with calculation of all required
status data from the previous history.
The PLC interface is updated in this block search and matching processes, which cover the interaction of several
channels executed within the framework of this block search correctly.
Search process with FXS and FOC
The user selects
FXS
or
FOC
in a program area of the searched target block in order to acquire all states and
functions of this machining last valid. The NC will start the selected program in Program test mode automatically.
After the target block has been found, the NC stops at the beginning of the target block, deselects Program test
internally again and displays the Stop condition "Search target found" in its block display.
If
FXS
"travel to fixed stop" is located between the beginning of the program and the search target, the instruction
is not really executed by the NC. The motion is only simulated up to the programmed end point.
The user can log the turning on and turning off of
FXS
in the parts program. If necessary, the user can start an
ASUB in order to activate or deactivate
FXS
in this SERUPRO-ASUP.
$AA_FXS and $VA_FXS
The meaning of system variable $AA_FXS is redefined for SERUPRO only and completely replaced by variable
$VA_FXS. Variables $AA_FXS and $VA_FXS have the same values continuously outside the SERUPRO
function.
CAUTION
SERUPRO approach does not really take the statement
FXS
into account. The approach to
the programmed end position of the
FXS
block is only simulated without torque limitation.
Description
NCK Variables
Axis not at fixed stop
$AA_FXS = 0 and $VA_FXS = 0
Fixed stop successfully approached
$AA_FXS = 1 and $VA_FXS = 1
Approach to fixed stop failed
$AA_FXS = 2 and $VA_FXS = 2
Travel to fixed stop selection active
$AA_FXS = 3 and $VA_FXS = 3
Fixed stop detected
$AA_FXS = 4 and $VA_FXS = 4
Travel to fixed stop deselection active
$AA_FXS = 5 and $VA_FXS = 5
Содержание SINUMERIK 828D Turning
Страница 34: ...Basic Functions 34 Function Manual 09 2011 6FC5397 0BP40 2BA0 ...
Страница 146: ...A3 Axis Monitoring Protection Zones 2 6 Data lists Basic Functions 146 Function Manual 09 2011 6FC5397 0BP40 2BA0 ...
Страница 328: ...F1 Travel to fixed stop 6 5 Data lists Basic Functions 328 Function Manual 09 2011 6FC5397 0BP40 2BA0 ...
Страница 816: ...K2 Axis Types Coordinate Systems Frames 10 9 Data lists Basic Functions 816 Function Manual 09 2011 6FC5397 0BP40 2BA0 ...
Страница 1198: ...P4 PLC for SINUMERIK 828D 14 6 Function interface Basic Functions 1198 Function Manual 09 2011 6FC5397 0BP40 2BA0 ...
Страница 1752: ...Appendix 20 2 Overview Basic Functions 1752 Function Manual 09 2011 6FC5397 0BP40 2BA0 ...
Страница 1774: ...Glossary Basic Functions 1774 Function Manual 09 2011 6FC5397 0BP40 2BA0 ...