D1: Diagnostics tools
5.3 Service overview
Basic Functions
286
Function Manual, 09/2011, 6FC5397-0BP40-2BA0
Speed lower than threshold setting
Status display of drive.
State 0: The actual speed value is greater than the threshold speed.
Status 1: The actual speed value is smaller than the threshold speed.
The threshold speed corresponds to machine datum:
MD1417 $MD_SPEED_THRESHOLD_X
(n
x
for 'n
actual
< n
x
' message).
Display corresponds to NST DB31, ... DBX94.5 ("|n
actual|
< n
x
").
References:
/FB1/ Function Manual Basic Functions; Various Interface Signals (A2)
Actual speed = set speed
Status display of drive.
The speed tolerance band corresponds to machine datum:
MD1426 $MD_SPEED_DES_EQ_ACT_TOL (tolerance band for 'n
set
-n
actual
' message).
Display corresponds to NST DB31, ... DBX94.6 ("|n
actual
|= n
set
").
References:
/FB1/ Function Manual Basic Functions; Various Interface Signals (A2)
Variable signal 1
Status display of 611D variable signaling function.
With the variable signaling function, any memory location can be monitored to see whether a definable threshold
is exceeded. In addition to the threshold, a tolerance band can be defined which is also taken into account when
scanning for violation of the threshold value. The signal can be combined with an ON delay or OFF delay time.
State 0: Threshold value not reached
State 1: Threshold value exceeded
Parameters for the variable signal function are set using the following 611D machine data:
State 0:
The actual speed value is outside the speed tolerance band after a
new speed setpoint was defined.
State 1:
The actual speed value has reached the speed tolerance band after a new
speed setpoint was defined.
MD1620 $MD_PROG_SIGNAL_FLAGS
(Bits variable signal function)
MD1621 $MD_PROG_SIGNAL_NR
(Signal number variable signal function)
MD1622 $MD_PROG_SIGNAL_ADDRESS
(Address variable signal function)
MD1623 $MD_PROG_SIGNAL_THRESHOLD (Threshold variable signal function)
MD1624 $MD_PROG_SIGNAL_HYSTERESIS (Hysteresis variable signal function)
MD1625 $MD_PROG_SIGNAL_ON_DELAY
(ON Delay variable signal function)
MD1626 $MD_PROG_SIGNAL_OFF_DELAY
(OFF Delay variable signal function)
Содержание SINUMERIK 828D Turning
Страница 34: ...Basic Functions 34 Function Manual 09 2011 6FC5397 0BP40 2BA0 ...
Страница 146: ...A3 Axis Monitoring Protection Zones 2 6 Data lists Basic Functions 146 Function Manual 09 2011 6FC5397 0BP40 2BA0 ...
Страница 328: ...F1 Travel to fixed stop 6 5 Data lists Basic Functions 328 Function Manual 09 2011 6FC5397 0BP40 2BA0 ...
Страница 816: ...K2 Axis Types Coordinate Systems Frames 10 9 Data lists Basic Functions 816 Function Manual 09 2011 6FC5397 0BP40 2BA0 ...
Страница 1198: ...P4 PLC for SINUMERIK 828D 14 6 Function interface Basic Functions 1198 Function Manual 09 2011 6FC5397 0BP40 2BA0 ...
Страница 1752: ...Appendix 20 2 Overview Basic Functions 1752 Function Manual 09 2011 6FC5397 0BP40 2BA0 ...
Страница 1774: ...Glossary Basic Functions 1774 Function Manual 09 2011 6FC5397 0BP40 2BA0 ...