V1: Feedrates
17.5 Supplementary conditions
Basic Functions
1412
Function Manual, 09/2011, 6FC5397-0BP40-2BA0
Activation of the F values
Machine data:
MD22140 F_VALUES_ACTIVE_AFTER_RESET (F function active via
RESET
)
can be used to define whether the following most recently programmed
F
values are to remain active following a
RESET
.
• Programmed path feedrate:
F=...
• Programmed feedrate change for path feedrate:
OVR=...
• Programmed positioning feedrate:
FA=...
• Programmed feedrate change for positioning feedrate:
OVRA[U]=...
For more detailed information about syntax, please see:
References:
/PG/ Programming Guide, Fundamentals
Position spindle
If
G95,G96,G961,G97,G971,G33,G34,G35
is active, spindle positioning should not be performed, because
the derived path feedrate following spindle positioning = 0.
⇒ If the programmed axis position has not yet been reached, the block cannot be completed.
Содержание SINUMERIK 828D Turning
Страница 34: ...Basic Functions 34 Function Manual 09 2011 6FC5397 0BP40 2BA0 ...
Страница 146: ...A3 Axis Monitoring Protection Zones 2 6 Data lists Basic Functions 146 Function Manual 09 2011 6FC5397 0BP40 2BA0 ...
Страница 328: ...F1 Travel to fixed stop 6 5 Data lists Basic Functions 328 Function Manual 09 2011 6FC5397 0BP40 2BA0 ...
Страница 816: ...K2 Axis Types Coordinate Systems Frames 10 9 Data lists Basic Functions 816 Function Manual 09 2011 6FC5397 0BP40 2BA0 ...
Страница 1198: ...P4 PLC for SINUMERIK 828D 14 6 Function interface Basic Functions 1198 Function Manual 09 2011 6FC5397 0BP40 2BA0 ...
Страница 1752: ...Appendix 20 2 Overview Basic Functions 1752 Function Manual 09 2011 6FC5397 0BP40 2BA0 ...
Страница 1774: ...Glossary Basic Functions 1774 Function Manual 09 2011 6FC5397 0BP40 2BA0 ...