Z1: NC/PLC interface signals
19.12 Feeds (V1)
Basic Functions
1734
Function Manual, 09/2011, 6FC5397-0BP40-2BA0
DB31, ...
DBX82.3
Change gear
Edge evaluation: yes
Signal(s) updated: Cyclic
Specification of gear stage:
• Manual specification using M function
M41
-
M45
corresponding to gear stage 1 - 5
If set gear stage <> actual gear stage =>
DB31, ... DBX82.3 (change gear) = 1
DB31, ... DBX82.0 - DBX82.2 (set gear stage) = set gear stage
• Automatic gear stage selection depending on the progr. Spindle speed via M-function
M4
0
at specified setpoint speed requires gear stage change =>
DB31, ... DBX82.3 (change gear) = 1
DB31, ... DBX82.0 - DBX82.2 (setpoint gear stage) = setpoint gear stage
Signal state 1 or
edge change
0 → 1
New set gear stage was specified AND
set gear stage <> actual gear stage
Special cases,
errors, ......
Signal is not output if: Set gear stage == actual gear stage
Corresponding to ...
DB31, ... DBX82.0 - DBX82.2 (Setpoint gear stage A to C)
DB31, ... DBX16.0 - 16.2 (Actual gear stage A to C)
DB31, ... DBX16.3 (gear is changed)
DB31, ...
DBX83.0
Speed limit exceeded
Edge evaluation: yes
Signal(s) updated: Cyclic
Signal state 1 or
edge change
0 → 1
The actual speed exceeds the maximum spindle speed:
MD35100 $MA_SPIND_VELO_ LIMIT
by more than the spindle speed tolerance:
MD35150 $MA_SPIND_DES_VELO_TOL
Corresponding to ...
MD35150 $MA_SPIND_DES_VELO_TOL (spindle speed tolerance)
MD35100 $MA_SPIND_VELO_LIMIT (maximum spindle speed)
DB31, ...
DBX83.1
Setpoint speed limited (programmed speed too high)
Edge evaluation: yes
Signal(s) updated: Cyclic
Signal state 1 or
edge change
0 → 1
The effective setpoint speed exceeds the actual max. limit value. The setpoint speed is limited to this
limit.
Limit values:
• MD35130 $MA_GEAR_STEP_MAX_VELO_LIMIT (maximum speed of gear stage)
• MD35100 $MA_SPIND_VELO_LIMIT (max. spindle speed)
• DB31, ... DBX3.6 (spindle speed limitation to MD35160 $MA_SPIND_EXTERN_VELO_LIMIT)
•
G26
(upper spindle speed limitation)
• LIMS (speed limitation for the master spindle if G96/G961/G97 is active)
•
VELOLIM
: Programmed spindle speed limitation in the open-loop speed controlled mode
• Safety Integrated
MD36931 $MA_SAFE_VELO_LIMIT (limit value for safely-reduced speed)
Signal state 0 or
edge change
1 → 0
The effective setpoint speed of the spindle is outside the maximum limit value.
Содержание SINUMERIK 828D Turning
Страница 34: ...Basic Functions 34 Function Manual 09 2011 6FC5397 0BP40 2BA0 ...
Страница 146: ...A3 Axis Monitoring Protection Zones 2 6 Data lists Basic Functions 146 Function Manual 09 2011 6FC5397 0BP40 2BA0 ...
Страница 328: ...F1 Travel to fixed stop 6 5 Data lists Basic Functions 328 Function Manual 09 2011 6FC5397 0BP40 2BA0 ...
Страница 816: ...K2 Axis Types Coordinate Systems Frames 10 9 Data lists Basic Functions 816 Function Manual 09 2011 6FC5397 0BP40 2BA0 ...
Страница 1198: ...P4 PLC for SINUMERIK 828D 14 6 Function interface Basic Functions 1198 Function Manual 09 2011 6FC5397 0BP40 2BA0 ...
Страница 1752: ...Appendix 20 2 Overview Basic Functions 1752 Function Manual 09 2011 6FC5397 0BP40 2BA0 ...
Страница 1774: ...Glossary Basic Functions 1774 Function Manual 09 2011 6FC5397 0BP40 2BA0 ...