A3: Axis Monitoring, Protection Zones
2.3 Protection zones
Basic Functions
120
Function Manual, 09/2011, 6FC5397-0BP40-2BA0
2.3.6
Protection-zone violation and temporary enabling of individual protection zones
Function
Workpiece and toolrelated protection zones that are activated or deactivated are monitored for collision. If a
protection-zone violation is detected, behavior in the individual operating modes is as follows.
Terminating temporary enabling
Temporary enabling of a protection zone is terminated after the following events:
• after
NC RESET
• Operating modes AUTOMATIC or MDA End of block is outside the protection zone
• Manual operating modes: End of movement is outside the protection zone
• Activating a protection zone
On
NC RESET
all the enabled protection zones become active again. If the part program or jog mode is started
again, the protection zones must be reenabled. If the current position lies within a protection zone that becomes
active again after
NC RESET
, this protection zone must be enabled again on the first path movement.
Preactivated protection zones
Protection zones can be preactivated with part programs. To make them fully operative, they must also be set to
the "operative" state by the PLC.
In contrast to AUTOMATIC mode, a change in the NC/PLC interface signals "Make preactivated protection zones
operative" only has an effect on stationary axes in the geometry system. This means: If an inoperative protection
zone is made "operative" once a motion has been started, it is not evaluated until the axes have stopped,
possibly resulting in the output of an alarm.
If a preactivated protection zone is made "operative" during traversing, the alarm 10704 "Protection-zone
monitoring is not guaranteed" and the PLC interface signal are set:
DB31, ... DBX39.0 (protection-zone monitoring not guaranteed).
Deactivation of toolrelated protection zones
Toolrelated protection zones can be deactivated only in the part program or, if they have been preactivated, by
being rendered "inoperative" by the PLC.
Geometry axis change and transformation change
Through the following machine data it is adjustable, whether active protection zones are retained or deactivated
during the geometry axis change or transformation change:
MD10618 $MN_PROTAREA_GEOAX_CHANGE_MODE
Bit
Value
Significance
0
0
Protection zones are deactivated during the transformation change.
1
Active protection zones remain active after a transformation is changed.
1
0
Protection zones are deactivated during the geometry axis change.
1
Active protection zones remain active after a geometry axis change.
Содержание SINUMERIK 828D Turning
Страница 34: ...Basic Functions 34 Function Manual 09 2011 6FC5397 0BP40 2BA0 ...
Страница 146: ...A3 Axis Monitoring Protection Zones 2 6 Data lists Basic Functions 146 Function Manual 09 2011 6FC5397 0BP40 2BA0 ...
Страница 328: ...F1 Travel to fixed stop 6 5 Data lists Basic Functions 328 Function Manual 09 2011 6FC5397 0BP40 2BA0 ...
Страница 816: ...K2 Axis Types Coordinate Systems Frames 10 9 Data lists Basic Functions 816 Function Manual 09 2011 6FC5397 0BP40 2BA0 ...
Страница 1198: ...P4 PLC for SINUMERIK 828D 14 6 Function interface Basic Functions 1198 Function Manual 09 2011 6FC5397 0BP40 2BA0 ...
Страница 1752: ...Appendix 20 2 Overview Basic Functions 1752 Function Manual 09 2011 6FC5397 0BP40 2BA0 ...
Страница 1774: ...Glossary Basic Functions 1774 Function Manual 09 2011 6FC5397 0BP40 2BA0 ...