B2: Acceleration
4.2 Functions
Basic Functions
250
Function Manual, 09/2011, 6FC5397-0BP40-2BA0
Substitute characteristic curve with linear path sections
Limitation to this value is applied if the programmed path velocity is greater than that at which 15 % of the
maximum acceleration capacity is still available (v
15%a
). Consequently, 15 % of the maximum acceleration
capacity/motor torque always remains available, whatever the machining situation.
Figure 4-10 Substitute path characteristic curve: Linear path
a
ers
:
Substitute characteristic curve constant acceleration
a
15%
:
Minimal constant acceleration
a
15%
= 0.15 * (a
max
- a
red
) + a
red
v
ers
:
Substitute characteristic curve velocity
v
prog
:
Programmed velocity
v
15%a
:
Velocity at a
15%
/RFNHG]RQH
YD
YSURJ
D
DHUV
DUHG
DPD[
YUHG
YPD[
D
Y
Содержание SINUMERIK 828D Turning
Страница 34: ...Basic Functions 34 Function Manual 09 2011 6FC5397 0BP40 2BA0 ...
Страница 146: ...A3 Axis Monitoring Protection Zones 2 6 Data lists Basic Functions 146 Function Manual 09 2011 6FC5397 0BP40 2BA0 ...
Страница 328: ...F1 Travel to fixed stop 6 5 Data lists Basic Functions 328 Function Manual 09 2011 6FC5397 0BP40 2BA0 ...
Страница 816: ...K2 Axis Types Coordinate Systems Frames 10 9 Data lists Basic Functions 816 Function Manual 09 2011 6FC5397 0BP40 2BA0 ...
Страница 1198: ...P4 PLC for SINUMERIK 828D 14 6 Function interface Basic Functions 1198 Function Manual 09 2011 6FC5397 0BP40 2BA0 ...
Страница 1752: ...Appendix 20 2 Overview Basic Functions 1752 Function Manual 09 2011 6FC5397 0BP40 2BA0 ...
Страница 1774: ...Glossary Basic Functions 1774 Function Manual 09 2011 6FC5397 0BP40 2BA0 ...