16962
[Channel %1: ] NCK computing time reduced, start is not allowed.
Parameters:
%1 = Channel number
Explanation:
The computing time available to the NCK has been reduced, starts have therefore been locked. The computer performance
is inadequate for smooth program execution. The computing time of the NCK may have been reduced by the HMI because
of an HMI part program simulation.
Reaction:
Alarm display.
Remedy:
Wait for the simulation to end or press RESET in any channel.
Programm
continuation:
Clear alarm with the Delete key or NC START.
16963
[Channel %1: ] ASUB start declined
Parameters:
%1 = Channel number
Explanation:
An external ASUB start fom the canceled program state has been declined for the following reasons:
- Bit 0 is not set in MD11602 $MN_ASUP_START_MASK
- ASUB priority has been set too low or MD11604 $MN_ASUP_START_PRIO_LEVEL has been set too high
Reaction:
Alarm display.
Remedy:
Correct the machine data or change the priority of the ASUB to be executed.
Programm
continuation:
Clear alarm with the Delete key or NC START.
16964
[Channel %1: ] Executing of init blocks not fully completed
Parameters:
%1 = Channel number
Explanation:
Init blocks are processed during ramp-up; they ensure that the control is initialized correctly. The alarm is set if processing
could not be completed correctly (usually due to alarms which were already pending).
Reaction:
Alarm display.
Remedy:
Eliminate pending alarms.
Programm
continuation:
Switch control OFF - ON.
16966
[Channel %1: ] Action %2<ALNX> prohibited during Jog Retract
Parameters:
%1 = Channel number
%2 = Action number/action name
Explanation:
The function (2nd parameter) must not be activated during Jog Retract.
Reaction:
Alarm display.
Remedy:
End Jog Retract by Reset.
Programm
continuation:
Clear alarm with the Delete key or NC START.
16967
[Channel %1: ] Action %2<ALNX> while preparing the protection areas not permissible
Parameters:
%1 = Channel number
%2 = Action number/action name
Explanation:
The function (2nd parameter) must not be activated while the protection areas, which are activated using the PI
_N_PROT_A, are being prepared.
Reaction:
Alarm display.
Remedy:
Wait until PI _N_PROT_A has been completed, or cancel PI with a RESET.
Programm
continuation:
Clear alarm with the Delete key or NC START.
SINUMERIK 808D ADVANCED alarms
5.2 NCK alarms
Diagnostics Manual
270
Diagnostics Manual, 06/2015, 6FC5398-6DP10-0BA2
Содержание SINUMERIK 808D
Страница 528: ...SINUMERIK 808D ADVANCED alarms 5 6 PLC user alarms Diagnostics Manual 528 Diagnostics Manual 06 2015 6FC5398 6DP10 0BA2 ...
Страница 534: ...System responses 6 2 Cancel criteria for alarms Diagnostics Manual 534 Diagnostics Manual 06 2015 6FC5398 6DP10 0BA2 ...
Страница 560: ...Data backup 8 2 External data backup Diagnostics Manual 560 Diagnostics Manual 06 2015 6FC5398 6DP10 0BA2 ...
Страница 566: ...Appendix A Diagnostics Manual 566 Diagnostics Manual 06 2015 6FC5398 6DP10 0BA2 ...