Reaction:
Correction block is reorganized.
Interface signals are set.
Alarm display.
Remedy:
Disable tools offsets or
reset option packages that include the tool offset as a reduced function.
Programm
continuation:
Clear alarm with the RESET key. Restart part program
8100
[Channel %1: ] Block %2: function not possible
Parameters:
%1 = Channel number
%2 = Block number, label
Explanation:
- Impossible due to embargo regulations:
- 1. Synchronous actions: Writing of feed, override and axial offsets ($AA_VC, $AC_VC, $AA_OVR, $AA_VC and
$AA_OFF) from synchronous actions as well as Continuous Dressing can be programmed only once in a block.
- 2. Extended measurement: 'Cyclic measurement' (MEAC) and 'Measurement from synchronous action' is not possible.
- 3. Axis interpolation: The number of axes interpolating with one another must not exceed 4 (this also includes synchronous
coupling of axes via synchronous actions "DO POS[X]=$A..." "DO FA[X]=$A...").
Reaction:
Interpreter stop
NC Start disable in this channel.
Interface signals are set.
Alarm display.
NC Stop on alarm.
Remedy:
Modify part program.
Programm
continuation:
Clear alarm with the RESET key. Restart part program
8102
[Channel %1: ] Block %2 motion synchronous action: %3 function not possible
Parameters:
%1 = Channel number
%2 = Block number, line number
%3 = Synact ID
Explanation:
- Impossible due to embargo regulations:
- 1. Synchronous actions: Writing of feed, override and axial offsets ($AA_VC, $AC_VC, $AA_OVR, $AA_VC and
$AA_OFF) from synchronous actions as well as Continuous Dressing can be programmed only once in a block.
- 2. Extended measurement: 'Cyclic measurement' (MEAC) and 'Measurement from synchronous action' is not possible.
- 3. Axis interpolation: The number of axes interpolating with one another must not exceed 4 (this also includes synchronous
coupling of axes via synchronous actions "DO POS[X]=$A..." "DO FA[X]=$A...").
Reaction:
NC Start disable in this channel.
Interface signals are set.
Alarm display.
NC Stop on alarm.
Remedy:
Modify part program.
Programm
continuation:
Clear alarm with the RESET key. Restart part program
9000
Handwheel %1 failed
Parameters:
%1 = Handwheel number
Explanation:
For PROFIBUS/PROFINET only:
PROFIBUS handwheel has failed
Reaction:
Interface signals are set.
Alarm display.
Remedy:
Restore connection to PROFIBUS handwheel
SINUMERIK 808D ADVANCED alarms
5.2 NCK alarms
Diagnostics Manual
Diagnostics Manual, 06/2015, 6FC5398-6DP10-0BA2
95
Содержание SINUMERIK 808D
Страница 528: ...SINUMERIK 808D ADVANCED alarms 5 6 PLC user alarms Diagnostics Manual 528 Diagnostics Manual 06 2015 6FC5398 6DP10 0BA2 ...
Страница 534: ...System responses 6 2 Cancel criteria for alarms Diagnostics Manual 534 Diagnostics Manual 06 2015 6FC5398 6DP10 0BA2 ...
Страница 560: ...Data backup 8 2 External data backup Diagnostics Manual 560 Diagnostics Manual 06 2015 6FC5398 6DP10 0BA2 ...
Страница 566: ...Appendix A Diagnostics Manual 566 Diagnostics Manual 06 2015 6FC5398 6DP10 0BA2 ...