Reaction:
Interpreter stop
NC Start disable in this channel.
Interface signals are set.
Alarm display.
Remedy:
The step "Counterspindle: synchronizing" must be used in the other channels.
Programm
continuation:
Clear alarm with the RESET key. Restart part program
61210
[Channel %1: ] Block %2: Block search element not found
Parameters:
%1 = Channel number
%2 = Block number, label
Explanation:
The element specified for the block search does not exisit.
Reaction:
Interpreter stop
NC Start disable in this channel.
Interface signals are set.
Alarm display.
Remedy:
Repeat block search.
Programm
continuation:
Clear alarm with the RESET key. Restart part program
61211
[Channel %1: ] Block %2: Absolute reference missing
Parameters:
%1 = Channel number
%2 = Block number, label
Explanation:
An incremental indication was made, but the absolute reference is unknown.
Reaction:
Interpreter stop
NC Start disable in this channel.
Interface signals are set.
Alarm display.
Remedy:
Program an absolute position prior to using incremental indications.
Programm
continuation:
Clear alarm with the RESET key. Restart part program
61212
%[[Channel %1: ] Block %2: %]Wrong tool type
Parameters:
%1 = Channel number
%2 = Block number, label
Explanation:
The tool type is not suitable for machining.
Reaction:
Interpreter stop
NC Start disable in this channel.
Interface signals are set.
Alarm display.
Remedy:
Select a new tool type.
Programm
continuation:
Clear alarm with the RESET key. Restart part program
61213
[Channel %1: ] Block %2: Circle radius too small
Parameters:
%1 = Channel number
%2 = Block number, label
Explanation:
The programmed circle radius is too small.
Remedy:
Correct the circle radius, center point or end point.
SINUMERIK 808D ADVANCED alarms
5.3 Cycle alarms
Diagnostics Manual
406
Diagnostics Manual, 06/2015, 6FC5398-6DP10-0BA2
Содержание SINUMERIK 808D
Страница 528: ...SINUMERIK 808D ADVANCED alarms 5 6 PLC user alarms Diagnostics Manual 528 Diagnostics Manual 06 2015 6FC5398 6DP10 0BA2 ...
Страница 534: ...System responses 6 2 Cancel criteria for alarms Diagnostics Manual 534 Diagnostics Manual 06 2015 6FC5398 6DP10 0BA2 ...
Страница 560: ...Data backup 8 2 External data backup Diagnostics Manual 560 Diagnostics Manual 06 2015 6FC5398 6DP10 0BA2 ...
Страница 566: ...Appendix A Diagnostics Manual 566 Diagnostics Manual 06 2015 6FC5398 6DP10 0BA2 ...