![Siemens SINUMERIK 808D Скачать руководство пользователя страница 315](http://html.mh-extra.com/html/siemens/sinumerik-808d/sinumerik-808d_diagnostic-manual_374970315.webp)
20148
[Channel %1: ] Block %2 motion synchronous action: %3 internal error %4
Parameters:
%1 = Channel number
%2 = Block number, line number
%3 = Synact ID
%4 = Error code
Explanation:
An internal error has occurred during processing of a synchronous action. The error code is for diagnostics purposes.
Please make a note and contact the manufacturer.
Reaction:
NC Start disable in this channel.
Interface signals are set.
Alarm display.
NC Stop on alarm.
Remedy:
Change synchronous action.
Programm
continuation:
Clear alarm with the RESET key. Restart part program
20149
[Channel %1: ] Block %2 motion-synchronous action: %3 Index %4 is illegal
Parameters:
%1 = Channel number
%2 = Block number, line number
%3 = Synact ID
%4 = Index
Explanation:
An illegal index was used to access a variable in the motion-synchronous action. The illegal index is displayed.
Example: ... DO $R[$AC_MARKER[1]] = 100
The error occurs if the value of marker 1 is greater than the maximum permissible R-variable number.
PROFIBUS/PROFINET I/O:
An illegal slot / I/O area index was used while reading/writing data.
Cause:
1.: Slot / I/O area index >= max. number of available slots / I/O areas.
2.: Slot / I/O area index references a slot / I/O area that has not been configured.
3.: Slot / I/O area index references a slot / I/O area that has not been released for system variables.
Reaction:
NC Start disable in this channel.
Interface signals are set.
Alarm display.
NC Stop on alarm.
Remedy:
Use a valid index.
Programm
continuation:
Clear alarm with the RESET key. Restart part program
20170
[Channel %1: ] Machine data $AC_FIFO invalid
Parameters:
%1 = Channel number
Explanation:
the structure of the FIFO variable $AC_FIFO1 - $AC_FIFO10 determined by machine data MD28260
$MC_NUM_AC_FIFO, MD28262 $MC_START_AC_FIFO, MD28264 $MC_LEN_AC_FIFO, MD28266
$MC_MODE_AC_FIFO cannot be stored in the R variables field defined in MD28050 $MC_MM_NUM_R_PARAM.
Reaction:
NC Start disable in this channel.
Interface signals are set.
Alarm display.
Remedy:
Please inform the authorized personnel/service department. Increase the number of the R variables or reduce the FIFO
elements.
MD28050 $MC_MM_NUM_R_PARAM = MD28262 $MC_START_A MD28260 $MC_NUM_AC_FIFO *
(MD28264 $MC_LEN_A 6)
Programm
continuation:
Switch control OFF - ON.
SINUMERIK 808D ADVANCED alarms
5.2 NCK alarms
Diagnostics Manual
Diagnostics Manual, 06/2015, 6FC5398-6DP10-0BA2
315
Содержание SINUMERIK 808D
Страница 528: ...SINUMERIK 808D ADVANCED alarms 5 6 PLC user alarms Diagnostics Manual 528 Diagnostics Manual 06 2015 6FC5398 6DP10 0BA2 ...
Страница 534: ...System responses 6 2 Cancel criteria for alarms Diagnostics Manual 534 Diagnostics Manual 06 2015 6FC5398 6DP10 0BA2 ...
Страница 560: ...Data backup 8 2 External data backup Diagnostics Manual 560 Diagnostics Manual 06 2015 6FC5398 6DP10 0BA2 ...
Страница 566: ...Appendix A Diagnostics Manual 566 Diagnostics Manual 06 2015 6FC5398 6DP10 0BA2 ...