![Siemens SINUMERIK 808D Скачать руководство пользователя страница 186](http://html.mh-extra.com/html/siemens/sinumerik-808d/sinumerik-808d_diagnostic-manual_374970186.webp)
14038
[Channel %1: ] Block %2 involute not definable: end point error
Parameters:
%1 = Channel number
%2 = Block number, label
Explanation:
The programmed end point does not lie on the involute defined by the start point, radius and center point of the basic circle.
The deviation of the effective end radius from the programmed value is greater than the permissible value specified in
MD21015 $MC_INVOLUTE_RADIUS_DELTA.
Reaction:
Correction block is reorganized.
Interface signals are set.
Alarm display.
Remedy:
Modify part program.
Programm
continuation:
Clear alarm with NC START or RESET key and continue the program.
14039
[Channel %1: ] Block %2 involute: end point programmed several times
Parameters:
%1 = Channel number
%2 = Block number, label
Explanation:
With involute interpolation, either the end point with the geometry axis identifiers or the angle of rotation with AR=value
can be programmed. Simultaneous programming of end point and angle of rotation in one block is not allowed, since the
end point can thus not be defined exactly.
Reaction:
Correction block is reorganized.
Interface signals are set.
Alarm display.
Remedy:
Modify part program.
Programm
continuation:
Clear alarm with NC START or RESET key and continue the program.
14040
[Channel %1: ] Block %2 error in end point of circle
Parameters:
%1 = Channel number
%2 = Block number, label
Explanation:
In circular interpolation, either the circle radii for the initial point and the end point are further apart, or the circle center
points are further apart, than specified in the machine data.
1. In circle radius programming the starting and end points are identical, thus the circle position is not determined by starting
and end points.
2. Radii: The NCK calculates from the present start point and the other programmed circle parameters the radii for the
start and the end point.
An alarm message is issued if the difference between the circle radii is either
- greater than the value in the MD21000 $MC_CIRCLE_ERROR_CONST (for small radii, if the programmed radius is
smaller than the quotient of the machine data MD21000 $MC_CIRCLE_ERROR_CONST divided by MD21010
$MC_CIRCLE_ERROR_FACTOR), or
- greater than the programmed radius multiplied by the MD21000 $MC_CIRCLE_ERROR_FACTOR (for large radii, if the
programmed radius is greater than the quotient of the machine data MD21010 $MC_CIRCLE_ERROR_CONST divided
by MD21010 $MC_CIRCLE_ERROR_FACTOR).
3. Center points: A new circle center is calculated using the circle radius at the starting position. It lies on the mid-
perpendicular positioned on the connecting straight line from the starting point to the end point of the circle. The angle in
the radian measure between both straight lines from the starting point to the center calculated/programmed as such must
be lower than the root of 0.001 (corresponding to approx. 1.8 degrees).
Reaction:
Correction block is reorganized.
Interface signals are set.
Alarm display.
Remedy:
Please inform the authorized personnel/service department.
Check MD21000 $MC_CIRCLE_ERROR_CONST and MD21010 $MC_CIRCLE_ERROR_FACTOR. If the values are
within reasonable limits, the circle end point or the circle mid-point of the part program block must be programmed with
greater accuracy.
SINUMERIK 808D ADVANCED alarms
5.2 NCK alarms
Diagnostics Manual
186
Diagnostics Manual, 06/2015, 6FC5398-6DP10-0BA2
Содержание SINUMERIK 808D
Страница 528: ...SINUMERIK 808D ADVANCED alarms 5 6 PLC user alarms Diagnostics Manual 528 Diagnostics Manual 06 2015 6FC5398 6DP10 0BA2 ...
Страница 534: ...System responses 6 2 Cancel criteria for alarms Diagnostics Manual 534 Diagnostics Manual 06 2015 6FC5398 6DP10 0BA2 ...
Страница 560: ...Data backup 8 2 External data backup Diagnostics Manual 560 Diagnostics Manual 06 2015 6FC5398 6DP10 0BA2 ...
Страница 566: ...Appendix A Diagnostics Manual 566 Diagnostics Manual 06 2015 6FC5398 6DP10 0BA2 ...