Explanation:
The text length (_DF) in the engraving cycle is too short. This means that the text for engraving is longer than the specified
text length.
Reaction:
Interpreter stop
NC Start disable in this channel.
Interface signals are set.
Alarm display.
Remedy:
Enter longer text length
Programm
continuation:
Clear alarm with the RESET key. Restart part program
61177
[Channel %1: ] Block %2: polar text length > 360 degrees
Parameters:
%1 = Channel number
%2 = Block number, label
Explanation:
In the engraving cycle, the polar text length must not exceed 360 degrees.
Reaction:
Interpreter stop
NC Start disable in this channel.
Interface signals are set.
Alarm display.
Remedy:
Enter shorter text length.
Programm
continuation:
Clear alarm with the RESET key. Restart part program
61178
[Channel %1: ] Block %2: code page not present
Parameters:
%1 = Channel number
%2 = Block number, label
Explanation:
The specified code page is not supported by the cycle.
Reaction:
Interpreter stop
NC Start disable in this channel.
Interface signals are set.
Alarm display.
Remedy:
Use code page 1252.
Programm
continuation:
Clear alarm with the RESET key. Restart part program
61179
[Channel %1: ] Block %2: character does not exist, no.: %4
Parameters:
%1 = Channel number
%2 = Block number, label
%4 = Character number
Explanation:
The character entered in the text for engraving cannot be milled.
Reaction:
Interpreter stop
NC Start disable in this channel.
Interface signals are set.
Alarm display.
Remedy:
Enter another character.
Programm
continuation:
Clear alarm with the RESET key. Restart part program
61180
[Channel %1: ] Block %2: No name assigned to swivel data record
Parameters:
%1 = Channel number
%2 = Block number, label
Explanation:
Although there are several swivel data blocks, no unique names have been assigned.
SINUMERIK 808D ADVANCED alarms
5.3 Cycle alarms
Diagnostics Manual
398
Diagnostics Manual, 06/2015, 6FC5398-6DP10-0BA2
Содержание SINUMERIK 808D
Страница 528: ...SINUMERIK 808D ADVANCED alarms 5 6 PLC user alarms Diagnostics Manual 528 Diagnostics Manual 06 2015 6FC5398 6DP10 0BA2 ...
Страница 534: ...System responses 6 2 Cancel criteria for alarms Diagnostics Manual 534 Diagnostics Manual 06 2015 6FC5398 6DP10 0BA2 ...
Страница 560: ...Data backup 8 2 External data backup Diagnostics Manual 560 Diagnostics Manual 06 2015 6FC5398 6DP10 0BA2 ...
Страница 566: ...Appendix A Diagnostics Manual 566 Diagnostics Manual 06 2015 6FC5398 6DP10 0BA2 ...