400020
PLC mainentance request %1 : Initial data not plausible
Explanation:
Redefine the initial data in accordance with the documentation.
Error causes:
Too many alarms for the interval length
Time of first alarm too late
Time of first alarm greater than interval
Reaction:
Alarm display.
Remedy:
Specify correct initital data according to the documentation.
Programm
continuation:
Clear alarm with the Delete key or NC START.
400021
Wait until I/O access is possible
Explanation:
I/O access is not possible at the current time.
Reaction:
Alarm display.
Remedy:
Programm
continuation:
Clear alarm with the Delete key or NC START.
400022
The PLC functionality: %2 is not permitted.
Explanation:
PLC functionality: %2
The specified PLC functionality is not supported.
Reaction:
Alarm display.
Remedy:
You are not permitted to use the specified PLC functionality.
Programm
continuation:
Clear alarm with the Delete key or NC START.
400023
Arithmetic problem in UP (REAL-Operation) OB/SBR/INT %1 Netzwerk %2
Explanation:
Problems with REAL operands during the PLC-UP execution
%1 Module No.
%2 Network No.
Reaction:
Alarm display.
Remedy:
The variables used have to be checked for valid values.
Programm
continuation:
Clear alarm with the Delete key or NC START.
400024
Dynamically managed memory used up, area %1
Explanation:
Memory overflow in area corresponding to memory area identification
%1 = 1xx: dynamic RAM, xx refers to internal RAM class
%1 = 2: MMF (user project)
%1 = 3: buffered RAM
%1 = 4: UP-RAM
Reaction:
Alarm display.
Remedy:
With %1 = 1xx: Internal error due to too many external communications requirements
With %1 > 1: User project too large or too many operations
Programm
continuation:
Clear alarm with the Delete key or NC START.
400025
PLC Ctrl Energy: Error in DB 9906
Explanation:
PLC Ctrl Energy: DB 9906 has been deleted.
Reaction:
PLC Stop
SINUMERIK 808D ADVANCED alarms
5.5 PLC alarms
Diagnostics Manual
Diagnostics Manual, 06/2015, 6FC5398-6DP10-0BA2
525
Содержание SINUMERIK 808D
Страница 528: ...SINUMERIK 808D ADVANCED alarms 5 6 PLC user alarms Diagnostics Manual 528 Diagnostics Manual 06 2015 6FC5398 6DP10 0BA2 ...
Страница 534: ...System responses 6 2 Cancel criteria for alarms Diagnostics Manual 534 Diagnostics Manual 06 2015 6FC5398 6DP10 0BA2 ...
Страница 560: ...Data backup 8 2 External data backup Diagnostics Manual 560 Diagnostics Manual 06 2015 6FC5398 6DP10 0BA2 ...
Страница 566: ...Appendix A Diagnostics Manual 566 Diagnostics Manual 06 2015 6FC5398 6DP10 0BA2 ...