Clear alarm with NC START or RESET key and continue the program.
17500
[Channel %1: ] Block %2 axis %3 is not an indexing axis
Parameters:
%1 = Channel number
%2 = Block number, label
%3 = Axis name, spindle number
Explanation:
An indexing axis position has been programmed for an axis with the keywords CIC, CAC or CDC that has not been defined
as indexing axis in the machine data.
Reaction:
Correction block is reorganized.
Interface signals are set.
Alarm display.
Remedy:
Please inform the authorized personnel/service department. Remove programming instruction for indexing axis positions
(CIC, CAC, CDC) from the NC part program or declare the relevant axis to be an indexing axis.
Indexing axis declaration:
Modify MD30500: $MA_INDEX_AX_ASSIGN_POS_TAB (indexing axis assignment)
The axis will become an indexing axis when an assignment to an indexing position table was made in the stated MD. 2
tables are possible (input value 1 or 2).
Modify MD10900 $MN_INDEX_AX_LENGTH_POS_TAB_1
Modify MD10920 $MN_INDEX_AX_LENGTH_POS_TAB_2 (Number of positions for 1st/2nd indexing axis)
Standard value: 0 Maximum value: 60
Modify MD10910 $MN_INDEX_AX_POS_TAB_1 [n]
Modify MD10930 $MN_INDEX_AX_POS_TAB_2 [n]
(Positions of the 1st indexing axis) The absolute axis positions are entered. (The list length is defined via MD10900
$MN_INDEX_AX_LENGTH_POS_TAB_1).
Programm
continuation:
Clear alarm with NC START or RESET key and continue the program.
17501
[Channel %1: ] Block %2 indexing axis %3 with Hirth tool system is active
Parameters:
%1 = Channel number
%2 = Block number, label
%3 = Axis name
Explanation:
The 'Hirth tooth system' function is activated for the indexing axis. This axis can therefore approach only indexing positions,
a different travel movement of the axis is not possible.
It is not permissible to program PRESETON or PRESETONS.
Reaction:
Interpreter stop
NC Start disable in this channel.
Interface signals are set.
Alarm display.
NC Stop on alarm.
Remedy:
Please inform the authorized personnel/service department.
Correct part program.
Correct FC16 or FC18 call.
Deselect machine data MD30505 $MA_HIRTH_IS_ACTIVE.
Programm
continuation:
Clear alarm with the RESET key. Restart part program
17502
[Channel %1: ] Block %2 indexing axis %3 with Hirth tooth system stop is delayed
Parameters:
%1 = Channel number
%2 = Block number, label
%3 = Axis name
SINUMERIK 808D ADVANCED alarms
5.2 NCK alarms
Diagnostics Manual
Diagnostics Manual, 06/2015, 6FC5398-6DP10-0BA2
283
Содержание SINUMERIK 808D
Страница 528: ...SINUMERIK 808D ADVANCED alarms 5 6 PLC user alarms Diagnostics Manual 528 Diagnostics Manual 06 2015 6FC5398 6DP10 0BA2 ...
Страница 534: ...System responses 6 2 Cancel criteria for alarms Diagnostics Manual 534 Diagnostics Manual 06 2015 6FC5398 6DP10 0BA2 ...
Страница 560: ...Data backup 8 2 External data backup Diagnostics Manual 560 Diagnostics Manual 06 2015 6FC5398 6DP10 0BA2 ...
Страница 566: ...Appendix A Diagnostics Manual 566 Diagnostics Manual 06 2015 6FC5398 6DP10 0BA2 ...