Reaction:
NC Start disable in this channel.
Interface signals are set.
Alarm display.
NC Stop on alarm.
Remedy:
Please inform the authorized personnel/service department. Do not initiate mode change. Cause the PLC to check the
axis and make sure in the PLC program that the axis ends oscillation if such mode changes take place.
Programm
continuation:
Clear alarm with the RESET key. Restart part program
20077
[Channel %1: ] Axis %2 programmed position %4 is behind software limit switch %3
Parameters:
%1 = Channel number
%2 = Axis number
%3 = "+" or "-"
%4 = Target position
Explanation:
The axis is traversed as an oscillating axis and the target position (reversal position or end position) is located behind the
corresponding software limit switch. The axis is not traversed.
Reaction:
Local alarm reaction.
NC Start disable in this channel.
Interface signals are set.
Alarm display.
NC Stop on alarm.
Remedy:
Specify smaller target position.
Modify MD for SW limit switch.
Possibly activate another SW limit switch.
Programm
continuation:
Clear alarm with the RESET key. Restart part program
20078
[Channel %1: ] Axis %2 programmed position %4 is behind working area limit %3
Parameters:
%1 = Channel number
%2 = Axis number
%3 = "+" or "-"
%4 = Target position
Explanation:
The axis is traversed as an oscillating axis and the target position (reversal position or end position) is located behind the
corresponding effective working area limitation. The axis is not traversed.
Reaction:
Local alarm reaction.
NC Start disable in this channel.
Interface signals are set.
Alarm display.
NC Stop on alarm.
Remedy:
Specify smaller target position.
Deactivate working area limitation.
Set working area limitation differentially.
Programm
continuation:
Clear alarm with the RESET key. Restart part program
20079
[Channel %1: ] Axis %2 oscillation path %3 <= 0
Parameters:
%1 = Channel number
%2 = Axis number
%3 = Length
Explanation:
The axis is traversed as an oscillating axis and the distance to be traversed is smaller than or equal to zero. For example,
both reversal points are situated on an identical position, one reversal point was shifted against the oscillating direction
beyond the other reversal point. The axis is not traversed.
SINUMERIK 808D ADVANCED alarms
5.2 NCK alarms
Diagnostics Manual
308
Diagnostics Manual, 06/2015, 6FC5398-6DP10-0BA2
Содержание SINUMERIK 808D
Страница 528: ...SINUMERIK 808D ADVANCED alarms 5 6 PLC user alarms Diagnostics Manual 528 Diagnostics Manual 06 2015 6FC5398 6DP10 0BA2 ...
Страница 534: ...System responses 6 2 Cancel criteria for alarms Diagnostics Manual 534 Diagnostics Manual 06 2015 6FC5398 6DP10 0BA2 ...
Страница 560: ...Data backup 8 2 External data backup Diagnostics Manual 560 Diagnostics Manual 06 2015 6FC5398 6DP10 0BA2 ...
Страница 566: ...Appendix A Diagnostics Manual 566 Diagnostics Manual 06 2015 6FC5398 6DP10 0BA2 ...