Explanation:
Reaction:
Interpreter stop
NC Start disable in this channel.
Interface signals are set.
Alarm display.
Remedy:
- Correct specified starting point
Programm
continuation:
Clear alarm with the RESET key. Restart part program
61941
%[[Channel %1: ] Block %2: %]Helix radius too small
Parameters:
%1 = Channel number
%2 = Block number, label
Explanation:
Reaction:
Interpreter stop
NC Start disable in this channel.
Interface signals are set.
Alarm display.
Remedy:
- Increase helix radius
Programm
continuation:
Clear alarm with the RESET key. Restart part program
61942
%[[Channel %1: ] Block %2: %]Helix violates contour
Parameters:
%1 = Channel number
%2 = Block number, label
Explanation:
Reaction:
Interpreter stop
NC Start disable in this channel.
Interface signals are set.
Alarm display.
Remedy:
- Check helix radius and reduce in size, if possible
Programm
continuation:
Clear alarm with the RESET key. Restart part program
61943
%[[Channel %1: ] Block %2: %]Approach/retract motion violates contour
Parameters:
%1 = Channel number
%2 = Block number, label
Explanation:
Reaction:
Interpreter stop
NC Start disable in this channel.
Interface signals are set.
Alarm display.
Remedy:
- Reduce safety clearance SC, if possible
Programm
continuation:
Clear alarm with the RESET key. Restart part program
61944
%[[Channel %1: ] Block %2: %]Ramp path too short
Parameters:
%1 = Channel number
%2 = Block number, label
Explanation:
During oscillating insertion, the message "Ramp path too short" occurs if the tool moves less than the mill diameter
away from the insertion point on the ramp path or the machining depth is not reached.
SINUMERIK 808D ADVANCED alarms
5.3 Cycle alarms
Diagnostics Manual
Diagnostics Manual, 06/2015, 6FC5398-6DP10-0BA2
499
Содержание SINUMERIK 808D
Страница 528: ...SINUMERIK 808D ADVANCED alarms 5 6 PLC user alarms Diagnostics Manual 528 Diagnostics Manual 06 2015 6FC5398 6DP10 0BA2 ...
Страница 534: ...System responses 6 2 Cancel criteria for alarms Diagnostics Manual 534 Diagnostics Manual 06 2015 6FC5398 6DP10 0BA2 ...
Страница 560: ...Data backup 8 2 External data backup Diagnostics Manual 560 Diagnostics Manual 06 2015 6FC5398 6DP10 0BA2 ...
Страница 566: ...Appendix A Diagnostics Manual 566 Diagnostics Manual 06 2015 6FC5398 6DP10 0BA2 ...