3.
Locate the parameter which you desire to set.
You can also search for a parameter using the following softkeys:
Searches for the desired number or the name (or a part of the name)
of the parameter
Continues searching for the next match
4.
Enter the desired value in the blank and press this key to confirm.
5.
Press this softkey to save the modified value(s) after you finish the
parameter setting.
Further softkey operations are available for setting the basic drive
data:
Switches to the next drive
Switches to the previous drive
Resets the value of the selected parameter to default
Undoes the modified values and recalls the lastly used values
Setting both machine data and setting data in expert list
Five groups of machine data and three groups of setting data are included in the expert list.
Setting the machine data
+
1. Select the desired operating area.
2. Open the expert data list through the following softkey operations:
→
The following five groups of machine data are available:
General machine data
Channel-specific machine data
Operating in the system data management operating area
3.3 Setting both system machine data and setting data
Diagnostics Manual
18
Diagnostics Manual, 06/2015, 6FC5398-6DP10-0BA2
Содержание SINUMERIK 808D
Страница 528: ...SINUMERIK 808D ADVANCED alarms 5 6 PLC user alarms Diagnostics Manual 528 Diagnostics Manual 06 2015 6FC5398 6DP10 0BA2 ...
Страница 534: ...System responses 6 2 Cancel criteria for alarms Diagnostics Manual 534 Diagnostics Manual 06 2015 6FC5398 6DP10 0BA2 ...
Страница 560: ...Data backup 8 2 External data backup Diagnostics Manual 560 Diagnostics Manual 06 2015 6FC5398 6DP10 0BA2 ...
Страница 566: ...Appendix A Diagnostics Manual 566 Diagnostics Manual 06 2015 6FC5398 6DP10 0BA2 ...