61557
[Channel %1: ] Block %2: Impossible chamfer and radius of right edge of wheel
Parameters:
%1 = Channel number
%2 = Block number, label channel number
Explanation:
Remedy:
Check values in grinding wheel data
Programm
continuation:
Clear alarm with the RESET key. Restart part program
61558
[Channel %1: ] Block %2: Chamfer / shoulder height are larger than the retraction height
of the left edge of the grinding wheel
Parameters:
%1 = Channel number
%2 = Block number, label channel number
Explanation:
Remedy:
Check values in grinding wheel data
Programm
continuation:
Clear alarm with the RESET key. Restart part program
61559
[Channel %1: ] Block %2: Chamfer / shoulder height are larger than the retraction height
of the right edge of the grinding wheel
Parameters:
%1 = Channel number
%2 = Block number, label channel number
Explanation:
Remedy:
Check values in grinding wheel data
Programm
continuation:
Clear alarm with the RESET key. Restart part program
61560
[Channel %1: ] Block %2: Infeed in Z direction too big per stroke, or wheel too narrow
Parameters:
%1 = Channel number
%2 = Block number, label channel number
Explanation:
Remedy:
Reduce infeed path parameter or use other tool
Programm
continuation:
Clear alarm with the RESET key. Restart part program
61561
[Channel %1: ] Block %2: Feed left wheel edge is smaller than or equal to zero
Parameters:
%1 = Channel number
%2 = Block number, label channel number
Explanation:
Remedy:
Check values in grinding wheel data
Programm
continuation:
Clear alarm with the RESET key. Restart part program
61562
[Channel %1: ] Block %2: Feed right wheel edge is smaller than or equal to zero
Parameters:
%1 = Channel number
%2 = Block number, label channel number
Explanation:
Remedy:
Check values in grinding wheel data
Programm
continuation:
Clear alarm with the RESET key. Restart part program
SINUMERIK 808D ADVANCED alarms
5.3 Cycle alarms
Diagnostics Manual
Diagnostics Manual, 06/2015, 6FC5398-6DP10-0BA2
459
Содержание SINUMERIK 808D
Страница 528: ...SINUMERIK 808D ADVANCED alarms 5 6 PLC user alarms Diagnostics Manual 528 Diagnostics Manual 06 2015 6FC5398 6DP10 0BA2 ...
Страница 534: ...System responses 6 2 Cancel criteria for alarms Diagnostics Manual 534 Diagnostics Manual 06 2015 6FC5398 6DP10 0BA2 ...
Страница 560: ...Data backup 8 2 External data backup Diagnostics Manual 560 Diagnostics Manual 06 2015 6FC5398 6DP10 0BA2 ...
Страница 566: ...Appendix A Diagnostics Manual 566 Diagnostics Manual 06 2015 6FC5398 6DP10 0BA2 ...