background image

 

 

 

1 / 18 

www.netio-products.com 

PowerCable IQRF 901x  

Manual 

This manual assumes basic familiarity with the IQRF technology. It is not intended as an IQRF 
tutorial. It provides an overview of the device’s functions. 
 

PowerCable IQRF 901x behaves as a standard 

IQRF Interoperable

 device. The product supports 

SmartConnect

. It is subject to all guides and procedures issued by the IQRF Alliance. For useful 

documents, see: 

 

IQRF Alliance Tech Guide

  

 

https://www.iqrfalliance.org/iqrf-interoperability/

 

https://www.iqrfalliance.org/techDocs/

  

 

IQRF-StandardSensor-V014

  

(https://www.iqrfalliance.org/techdoc_files/IQRF-StandardSensor_V014.pdf) 

 

IQRF-StandardBinaryOutput-V004

 

https://www.iqrfalliance.org/techdoc_files/IQRF-StandardBinaryOutput_V004.pdf 

 

IQRF Quick Start Guide

  

(

http://www.iqrf.org/weben/downloads.php?id=235

) 

 

IQRF Glossary 

 

901x 

The NETIO products company supplies the PowerCable IQRF in several versions with 
different types of electrical sockets and plugs. The type is specified by the last character at the 
place of the “x” in 901x. 901

E

 = sockets for France, Czechia, Slovakia and Poland, 901

F

 = 

German (“schuko”) sockets used in most of Europe.  

 

Node

 

In an IQRF network, a Node is a device that performs its function (e.g. measures electrical 
current – PowerCable IQRF 901E) and, at the same time, acts as a hub for other Nodes. A 
Node connects to a Coordinator (Gateway), either directly, or through other Nodes. 

 

Coordinator

 

In the IQRF network, a Coordinator is a device (such as an IQRF Gateway) that controls 
network traffic and gathers data from individual Nodes. Connection of Nodes to the network is 
initiated at the Gateway. Nodes can be connected to the Coordinator either directly or through 
other Nodes. 

 

 

Содержание PowerCable IQRF 901 Series

Страница 1: ... Start Guide http www iqrf org weben downloads php id 235 IQRF Glossary 901x The NETIO products company supplies the PowerCable IQRF in several versions with different types of electrical sockets and plugs The type is specified by the last character at the place of the x in 901x 901E sockets for France Czechia Slovakia and Poland 901F German schuko sockets used in most of Europe Node In an IQRF ne...

Страница 2: ...network The cable plug serves as the disconnection means and must be easily accessible The electrical socket must be earthed and protected with a circuit breaker rated at 16A or less The manufacturer assumes no responsibility for any technical or printing errors and reserves the right to modify the product or this document without prior notice Such changes are announced at the manufacturer s websi...

Страница 3: ...e IQRF Daemon The IQRF Interoperable Gateway in turn provides a JSON API interface that is used for all communication and configuration of the IQRF network over a LAN For available IQRF Interoperable Gateways see https iqrf shop product gateways After setting up the IQRF Gateway according to its manufacturer s instructions the following web applications can be used to set up the IQRF network and v...

Страница 4: ...re https play google com store apps details id org iqrfalliance demo 1 When the app is started it needs the details to connect to the IQRF Interoperable Gateway The Gateway must be accessible in the LAN Websocket is used for the connection 2 When the connection is successfully established the current network status is loaded At the beginning the network is empty No nodes found ...

Страница 5: ...Bonding using some physical interaction with the device a button on the PowerCable IQRF AutoNetwork automatically connects all available devices with the same network key Example Connecting with the mobile app SmartConnect Connect the app to the IQRF Interoperable Gateway Click the blue circle with a plus symbol in the bottom right hand corner to add a device into the network using any of the avai...

Страница 6: ...yed After confirming the Smart Connect procedure starts The app informs about the progress and the result The message about a successful connection also shows the address assigned to the device All interoperable devices connected to the network are then listed in the home panel ...

Страница 7: ...1 Connect the module or the USB Gateway that acts as the Coordinator to the IQRF IDE 2 In the IQRF IDE open these windows Packet Inspector Terminal IQMESH Network Manager 3 In the IQMESH Network Manager go to the Control tab and enter address 4 in the IQMESH menu 4 Click Bond Node ...

Страница 8: ...ce can be unbonded in two ways 1 By the Coordinator use the Unbond Node function with the selected PowerCable address and confirm the unbonding at the remote device too 2 By the PowerCable IQRF unplug the PowerCable IQRF Press and hold the bonding button Reset icon and plug the device back in Hold the button pressed until the green LED Output icon lights up then release immediately Successful unbo...

Страница 9: ...rk by the coordinator If the device is unbonded by the PowerCable IQRF it will show up as Offline Such a device can be removed with the Unbond Device only from Coordinator function Example Unbonding from the IQRF network in the IQRF IDE 1 In the IQMESH Network Manager go to the Control tab and enter the address of the PowerCable IQRF to unbond in the IQMESH menu For example address 4 Leave the Pow...

Страница 10: ...10 18 www netio products com 2 Check Only In coordinator 3 Click Unbond Node and confirm ...

Страница 11: ...tation according to DPA Interoperable IQRF StandardBinaryOutput V004 https www iqrfalliance org techdoc_files IQRF StandardBinaryOutput_V004 pdf Output address 0x01 Example Switching the PowerCable output on in the mobile app Example Switching the PowerCable output on in the IQRF IDE In the IQRF IDE open these windows Packet Inspector Terminal Terminal Log Message header HEX NADR 0x0004 PNUM 0x4B ...

Страница 12: ...ample Switching the PowerCable output off in the IQRF IDE In the IQRF IDE open these windows Packet Inspector Terminal Terminal Log Message header HEX NADR 0x0004 PNUM 0x4B PCMD 0x00 HWPID 0x0003 Message data HEX PDATA 01 00 00 00 00 Response PDATA if the command is correctly received 04 00 4B 80 03 00 00 47 01 00 00 00 Previous output state on ...

Страница 13: ... this standard Documentation according to DPA Interoperable IQRF StandardSensor V014 https www iqrfalliance org techdoc_files IQRF StandardSensor_V014 pdf Example Reading all PowerCable IQRF sensors in the mobile app Addresses of individual sensors in PowerCable IQRF 901x Voltage Sensor 0 Sensor Type 0x06 Low Voltage PDATA Current Sensor 1 Sensor Type 0x07 Current PDATA Power Sensor 2 Sensor Type ...

Страница 14: ...on cannot be reset In this regard the PowerCable IQRF behaves as a regular power meter The date and time refer to the factory reset Example Reading all PowerCable IQRF sensors in IQRF IDE In the IQRF IDE open these windows Packet Inspector Terminal Terminal Log Message header HEX NADR 0x0004 PNUM 0x5E PCMD 0x01 HWPID 0x0003 Message data HEX PDATA 7F 00 00 00 Response PDATA if the command is correc...

Страница 15: ...able IQRF supports user configurable power on output state The following options are available OFF when the power is restored the output is always off and can only be switched on with a command over the IQRF network ON when the power is restored the output is always switched on within 2 seconds after powering up the device and can be only switched off with a command over the IQRF network LAST when...

Страница 16: ...d message data HEX PDATA 55 AA 00 09 01 00 2C Response PDATA if the command is correctly received 55 AA 00 05 00 27 Setting the power on state to ON address 0x0004 Message header HEX NADR 0x0004 PNUM 0x5E PCMD 0x40 HWPID 0x0003 1st message data HEX PDATA 55 AA 00 0A 01 00 2D Response PDATA if the command is correctly received 55 AA 00 05 00 27 2nd message data HEX PDATA 55 AA 00 09 01 01 2D Respon...

Страница 17: ...m Setting the power on state to LAST address 0x0004 Message header HEX NADR 0x0004 PNUM 0x5E PCMD 0x40 HWPID 0x0003 Message data HEX PDATA 55 AA 00 0A 01 01 2E Response PDATA if the command is correctly received 55 AA 00 05 00 27 ...

Страница 18: ... to applicable harmonized standards or other technical specifications with which conformity is hereby declared Article 3 1 a Protection of health and safety Article 3 1 b Electromagnetic compatibility Article 3 2 Effective and efficient use of radio spectrum Additional information Test protocol No EZÚ 700026 01 06 dated 31st January 2018 Test protocol No EZÚ 700026 01 09 dated 31st January 2018 Ro...

Отзывы: