HotWire 5034 Indoor POTS Splitter Customer
Premises
Installation Instructions
Document Number 5034-A2-GN10-10
October 1997
Before You Begin
Verify that:
5034 Indoor POTS Splitter
The local loop POTS service is
connected to the POTS/DSL network.
New or existing unshielded
twisted-pair wiring (CAT3 or better)
is used from the DSL jack to the
POTS splitter and from the POTS
splitter to the RTU. The CAT3
wiring must meet EIA/TIA-568
specifications with 24 AWG (.5 mm)
or 26 AWG (.4 mm).
Three cables are available that meet the CAT3 wiring specifications with RJ11
connectors at both ends. Refer to
Installing the 5034 POTS Splitter
, page 3.
Your package contains a POTS Splitter and a Warranty Card.
For RADSL (Rate Adaptive Digital Subscriber Line) RTU installation information, refer to
the appropriate RTU document:
Document Number
Document Title
5216-A2-GN10
HotWire 5216 Remote Termination Unit (RTU)
Customer Premises Installation Instructions
5246-A2-GN10
HotWire 5246 Remote Termination Unit (RTU)
Customer Premises Installation Instructions
5446-A2-GN10
HotWire 5446 Remote Termination Unit (RTU)
Customer Premises Installation Instructions