TM DRIVE-CLiQ: Telegram failure
Reaction: OFF2
Cause:
There is a DRIVE-CLiQ communication error between the control unit and the affected
terminal module.
Remedy:
- Check for break in DRIVE-CLiQ or faulty contacts in connector.
- Check 24 V supply of affected component.
- Replace affected component.
See also: p9916
Acknowl.: Immediate
F35833
TM DRIVE-CLiQ: fault in cyclic data transfer
Reaction: OFF2
Cause:
There is a DRIVE-CLiQ communication error between the control unit and the affected
terminal module.
Remedy:
- Check firmware states of affected components.
- Replace affected component.
Acknowl.: Immediate
F35834
TM DRIVE-CLiQ: Hardware defect
Reaction: OFF2
Cause:
There is a DRIVE-CLiQ communication error between the control unit and the affected
terminal module.
Remedy:
Replace affected component.
Acknowl.: Immediate
F35835
F35836
TM DRIVE-CLiQ: fault in cyclic data transfer
Reaction: OFF2
Cause:
There is a DRIVE-CLiQ communication error between the control unit and the affected
terminal module.
Remedy:
- Check firmware states of affected components.
- Replace affected component.
Acknowl.: Immediate
F35837
F35838
TM DRIVE-CLiQ: Hardware defect
Reaction: OFF2
Cause:
There is a DRIVE-CLiQ communication error between the control unit and the affected
terminal module.
Remedy:
Replace affected component.
Acknowl.: Immediate
F35860 -
F35871
CU DRIVE-CLiQ: Data transfer faulted / Telegram faulted
Reaction: OFF2
Cause:
DRIVE-CLiQ communication between control unit and at least one other component is
defective.
Fault value
(r0949):
Bit 0 - 7: Number of the affected component
Bit 8 - 31: Reserved
Remedy:
- Check cabinet design and cabling for EMC conformity.
- Replace affected component.
Acknowl.: Immediate
F35872
F35873
CU DRIVE-CLiQ: fault in cyclic data transfer
Reaction: OFF2
Cause:
Reserved for later use.
Remedy:
Reserved for later use.
Acknowl.: Immediate
Содержание SINAMICS G150
Страница 1: ...Operating Manual Edition 11 2003 sinamics Converter Cabinet Units SINAMICS G150 75 kW to 800 kW ...
Страница 2: ......
Страница 22: ...Device Overview 11 03 SINAMICS G150 2 10 Operating Manual ...
Страница 136: ...Monitoring Functions and Protective Functions 11 03 SINAMICS G150 9 2 Operating Manual 9 2 Monitoring in preparation ...
Страница 196: ...Diagnosis Faults and Alarms 11 03 SINAMICS G150 10 54 Operating Manual ...
Страница 208: ...Maintenance and Servicing 11 03 SINAMICS G150 11 12 Operating Manual ...
Страница 234: ......
Страница 238: ...Parameterlist 11 03 SINAMICS G150 Parameterlist 4 Operating Manual ...
Страница 239: ......