3. When stored for longer than two years, lubricate with twice the grease quantity in
accordance with the lubricant plate. This ensures that the grease is evenly distributed and
covers all surfaces. Corrosion damage is avoided.
NOTICE
Damage to roller bearings
Roller bearings can be damaged when kept in the same or almost the same position.
Every three months, manually rotate the rotor through five revolutions. Make sure that the
resting position of the roller bearings after the rotor has been turned is different from what
it previously had been. Use the feather key as a reference point, if present.
4. Replace the corrosion protection.
5. Reattach the rotor shipping brace, if present.
6. Pack the machine again.
4.18.6
Protecting the cooling water circuit during storage
When supplied, the machine is not filled with cooling water.
Protecting the cooling circuit against corrosion
You protect the cooling circuit against corrosion when the machine has already been in
operation and is then placed in storage or put out of operation.
1. Completely drain the cooling ducts. Blow out the cooling water ducts with compressed air.
1. Close and seal the intake and discharge.
4.18.7
Protection against corrosion
If the machine is stored in dry conditions, then apply the subsequently listed anti-corrosion
measures:
● Storage up to six months:
Apply a coat of corrosion protective compound to all accessible bare metal parts such as
the exposed shaft extension, flange or machine feet.
● Storage for longer than six months:
Apply a coat of long-term anti-corrosion agent to all accessible bare parts.
● Inspect the machine regularly and if necessary, apply an additional coating of corrosion
protection.
Document all preservation measures taken so that they can be reversed before the machines
are put back into service.
Preparations for use
4.18 Transport and storage
SIMOTICS FD 1MH1
Operating Instructions 08/2017
51
Содержание SIMOTICS FD 1LL1
Страница 2: ...18 08 2017 17 24 V10 00 ...
Страница 32: ...Description 3 1 Comparison of IEC and GOST standards SIMOTICS FD 1MH1 32 Operating Instructions 08 2017 ...
Страница 58: ...Preparations for use 4 19 Converter operation SIMOTICS FD 1MH1 58 Operating Instructions 08 2017 ...
Страница 104: ...Electrical connection 6 6 Connecting the auxiliary circuits SIMOTICS FD 1MH1 104 Operating Instructions 08 2017 ...
Страница 120: ...Start up 7 10 Setting the motor parameters at the converter SIMOTICS FD 1MH1 120 Operating Instructions 08 2017 ...
Страница 176: ...Disposal 11 4 Disposal of components SIMOTICS FD 1MH1 176 Operating Instructions 08 2017 ...
Страница 178: ...Service and Support SIMOTICS FD 1MH1 178 Operating Instructions 08 2017 ...
Страница 182: ...Quality documents SIMOTICS FD 1MH1 182 Operating Instructions 08 2017 ...
Страница 187: ......