4.13
Complying with speed-torque curve
WARNING
Exceeding the temperature class
If the speed-torque curve is not followed, the temperature class may be exceeded. An
explosion can occur. This can result in death, serious injury or material damage.
● Comply with the speed-torque curve.
● Observe the data on the extra rating plate on the motor.
4.14
Voltage and frequency fluctuations during line operation
If nothing else is stamped on the rating plate, the permissible voltage fluctuation is ±5 % and
the permissible frequency fluctuation is ±2 %, corresponding to range A in IEC/EN 60034-1.
Permissible fluctuations that go beyond these values are stamped on the rating plate.
Under operating conditions a machine may sometimes have to be operated outside the limits
of range A.
● Limit exceptions of this sort with regard to the values that arise, how often, and for how long
they occur.
● Where possible and within a reasonable time take corrective actions such as reducing the
power. Such actions can avoid thermal ageing leading to a reduction in the service life of
the machine.
NOTICE
Overheating of the winding
Exceeding the permissible tolerances for voltage and frequency can lead to an impermissibly
high temperature rise in the windings. This can result in long-term damage to the machine.
4.15
Phase synchronization during supply system switching
NOTICE
Supply system switching
Damage to the machine may be caused when switching to another supply system with
different phasing.
● The phasing must be synchronized during switching. Use appropriate means to
synchronize the phasing.
Preparations for use
4.13 Complying with speed-torque curve
SIMOTICS FD 1MH1
Operating Instructions 08/2017
43
Содержание SIMOTICS FD 1LL1
Страница 2: ...18 08 2017 17 24 V10 00 ...
Страница 32: ...Description 3 1 Comparison of IEC and GOST standards SIMOTICS FD 1MH1 32 Operating Instructions 08 2017 ...
Страница 58: ...Preparations for use 4 19 Converter operation SIMOTICS FD 1MH1 58 Operating Instructions 08 2017 ...
Страница 104: ...Electrical connection 6 6 Connecting the auxiliary circuits SIMOTICS FD 1MH1 104 Operating Instructions 08 2017 ...
Страница 120: ...Start up 7 10 Setting the motor parameters at the converter SIMOTICS FD 1MH1 120 Operating Instructions 08 2017 ...
Страница 176: ...Disposal 11 4 Disposal of components SIMOTICS FD 1MH1 176 Operating Instructions 08 2017 ...
Страница 178: ...Service and Support SIMOTICS FD 1MH1 178 Operating Instructions 08 2017 ...
Страница 182: ...Quality documents SIMOTICS FD 1MH1 182 Operating Instructions 08 2017 ...
Страница 187: ......