System-specific ignition hazards
The criteria for the respective zonal classification are not harmonized and the assessment of
the operational risks, the local operating conditions and the various monitoring methods are
not standard. As a consequence, the remedial measures recommended by the supervisory
authorities may also differ depending on the authority's area of responsibility. The machine
manufacturer cannot provide general recommendations in this regard.
Note
Binding clarification of the local risks and of any required measures can only be provided by
the company operating the plant or system in agreement with the supervisory authority
responsible. The risk assessments from IEC / EN 60079-15 or -7 can be used to assess system-
specific ignition hazards.
If you using antifreeze in the cooling water, ensure that the coolant temperature does not fall
below -15 °C.
8.3
Switching on the machine
1. If at all possible, run the machine without load and check that it is running smoothly.
2. If it runs perfectly, connect a load.
NOTICE
Thermal overload of motors connected directly to the line supply
In addition to the load torque, the ramp-up (accelerating) time is essentially influenced by
the moment of inertia to be accelerated. While ramping up when connected to the line
supply, the inrush (starting) current is a multiple of the rated current. This can result in
thermal overload. This can damage the motor.
As a consequence, when ramping up, observe the following:
● Monitor the ramp-up time and number of consecutive starts.
● Comply with the limit values and/or ramp-up conditions specified in the catalog or the
order documentation.
3. If this is possible using the available measuring equipment, check the bearing and stator
winding temperatures.
Operation
8.3 Switching on the machine
SIMOTICS FD 1MH1
Operating Instructions 08/2017
123
Содержание SIMOTICS FD 1LL1
Страница 2: ...18 08 2017 17 24 V10 00 ...
Страница 32: ...Description 3 1 Comparison of IEC and GOST standards SIMOTICS FD 1MH1 32 Operating Instructions 08 2017 ...
Страница 58: ...Preparations for use 4 19 Converter operation SIMOTICS FD 1MH1 58 Operating Instructions 08 2017 ...
Страница 104: ...Electrical connection 6 6 Connecting the auxiliary circuits SIMOTICS FD 1MH1 104 Operating Instructions 08 2017 ...
Страница 120: ...Start up 7 10 Setting the motor parameters at the converter SIMOTICS FD 1MH1 120 Operating Instructions 08 2017 ...
Страница 176: ...Disposal 11 4 Disposal of components SIMOTICS FD 1MH1 176 Operating Instructions 08 2017 ...
Страница 178: ...Service and Support SIMOTICS FD 1MH1 178 Operating Instructions 08 2017 ...
Страница 182: ...Quality documents SIMOTICS FD 1MH1 182 Operating Instructions 08 2017 ...
Страница 187: ......