8.12.4
Water cooling faults
The following table shows the possible causes of and remedial measures for faults on water-
cooled machines.
Table 8-3
Cooling system faults
↓ Overheating
↓ Water leaking
Possible causes of faults
Remedial measures
X
Reduced cooling
Check the cooling water flow, increase the amount of cooling water if
necessary.
X
Cooling water flow rate too low
Consult the manufacturer. If the specified cooling water quality is ob‐
served, the cooling system is maintenance-free.
X
Inlet temperature too high
Set the correct upstream temperature.
X
Cooling water supply switched off
Switch on the cooling water supply.
X
Cooling water contains too many or unsuit‐
able antifreeze and corrosion-protection
agents
Use cooling water of the agreed quality.
X Leaks in the cooling system
Consult the manufacturer.
X Defective cooling water connection
Find the leak and seal it.
Operation
8.12 faults
SIMOTICS FD 1MH1
Operating Instructions 08/2017
131
Содержание SIMOTICS FD 1LL1
Страница 2: ...18 08 2017 17 24 V10 00 ...
Страница 32: ...Description 3 1 Comparison of IEC and GOST standards SIMOTICS FD 1MH1 32 Operating Instructions 08 2017 ...
Страница 58: ...Preparations for use 4 19 Converter operation SIMOTICS FD 1MH1 58 Operating Instructions 08 2017 ...
Страница 104: ...Electrical connection 6 6 Connecting the auxiliary circuits SIMOTICS FD 1MH1 104 Operating Instructions 08 2017 ...
Страница 120: ...Start up 7 10 Setting the motor parameters at the converter SIMOTICS FD 1MH1 120 Operating Instructions 08 2017 ...
Страница 176: ...Disposal 11 4 Disposal of components SIMOTICS FD 1MH1 176 Operating Instructions 08 2017 ...
Страница 178: ...Service and Support SIMOTICS FD 1MH1 178 Operating Instructions 08 2017 ...
Страница 182: ...Quality documents SIMOTICS FD 1MH1 182 Operating Instructions 08 2017 ...
Страница 187: ......